background image

TABLE OF CONTENTS

Thank You for purchasing this 

Wells Bloomfield appliance.

Proper installation, professional 

operation and consistent

maintenance of this appliance will 

ensure that it gives you the very 

best  performance  and  a  long, 

economical service life. 

This manual contains the

information needed to properly 

install this appliance, and to use, 

care for and maintain or repair the 

appliance in a manner which will 

ensure its optimum performance.

WARRANTY STATEMENT 

xi

SPECIFICATIONS 

 1

FEATURES & OPERATING CONTROLS 

  2

PRECAUTIONS & GENERAL INFORMATION 

  4

AGENCY APPROVAL INFORMATION 

  4

INSTALLATION 

  5  

OPERATION 

  7

CLEANING INSTRUCTIONS 

10

SERVICING INSTRUCTIONS 

12

Delime the water tank  

12

Draining hot water tank 

13

Timer Adjustment 

14

Temperature Adjustment 

15

TROUBLESHOOTING SUGGESTIONS 

16

EXPLODED VIEWS 

17

WIRING DIAGRAM 

26

1

SPECIFICATIONS

671   2M-Z16955 Owners Manual 9221  Dual Satellite Brewer

22 1/16”

560 mm

3 5/16”

84 mm

6 3/8”

162 mm

4 1/2”

114 mm

5 13/16”

148 mm

16 15/32”

418 mm

5 1/4”

133 mm

6 1/4”

159 mm

19 9/16”

497 mm

16 7/16”

417 mm

LINE CORD

LOCATION

ON BASE

DIMENSION SHOWN IS WITHOUT STRAINER

ASSY, ALLOW ADDITIONAL 5 INCHES

OPTIONAL DRIP TRAY

(P/N WS-3901)

WATER INLET

ON BASE

WATER LINE

ON BASE

19 5/32”

486 mm

29 5/16”

744 mm

IL2302a, M671

MODEL

VOLTS

Hz

WATTS

AMPS

POWER CORD

60 Hz 1ø

9221

120/208-240V

60 Hz 1ø 4700/6250

23/26A

Requires 3-wire (L1, L2, N plus Gnd) cord 

 - not provided 

9121

120/240V 3/W N

50/60 Hz 1ø

3150

26.25/13.125

120V

1650

13.7

5-15P

230V

3150

Requires 3-wire (L1, L2, N plus Gnd) cord - not provided 

Содержание 9121

Страница 1: ...omfield com p n 2M Z16955 Rev B M671 131114 671 OWNERS MANUAL for SINGLE DUAL SATELLITE COFFEE BREWER with ELECTRO MECHANICAL CONTROL and EXTERNALLY HEATED SATELLITE SERVERS MODEL 9121 9221 Includes Installation Operation Use Care Servicing Instructions Model 9121 Single Satellite Brewer ...

Страница 2: ...ecanters c decanters are not covered by this warranty THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY EXCLUDED BLOOMFIELD LLC SHALL NOT BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER This warranty is ...

Страница 3: ...Delime the water tank 12 Draining hot water tank 13 Timer Adjustment 14 Temperature Adjustment 15 TROUBLESHOOTING SUGGESTIONS 16 EXPLODED VIEWS 17 WIRING DIAGRAM 26 1 SPECIFICATIONS 671 2M Z16955 Owners Manual 9221 Dual Satellite Brewer 22 1 16 560 mm 3 5 16 84 mm 6 3 8 162 mm 4 1 2 114 mm 5 13 16 148 mm 16 15 32 418 mm 5 1 4 133 mm 6 1 4 159 mm 19 9 16 497 mm 16 7 16 417 mm LINE CORD LOCATION ON ...

Страница 4: ...Fig 1 SS 2 Satellite Brewing System Features Operating Controls 671 2M Z16955 Owners Manual 9221 Dual Satellite Brewer IL2303a M671 BREW CHAMBER IN POSITION FUSE BEHIND FRONT PANEL SALELLITE IN POSITION HOT WATER FAUCET WARMER SWITCHES ...

Страница 5: ...mber Also lists voltage and wattage rating of brewer Glows when the tank water is up to temperature Located on lower right rear of brewer Turns main power to brewer ON or OFF Positions externally heated satellite on brewer Maintains temperature of product in satellite Control individual warmers for externally heated satellite Holds coffee grounds during brew cycle Forms dilution flow channel by ho...

Страница 6: ... procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagrams schematics parts breakdown illustrations notices and labels must remain with the appliance if it is sold or moved to another location This appliance is made in the USA Unless otherwise noted this ...

Страница 7: ... tubing for installations exceeding 12 Brewer must be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must be installed between the main water supply and the brewer Plumbing installer must supply the shut off valve A 1 4 turn ball valve is recommended Bloomfield highly recommends the use of the provided water strainer to help prevent depo...

Страница 8: ... BREWER FOR PROPER CONFIGURATION Make sure spray disk gaskets are in place INSIDE of spray heads Make sure spray disks are properly installed Check hot water faucet for proper operation and leaks Place empty satellites in position 2 START BREWER OPERATION Be sure HEATER ON OFF switch is OFF then press POWER SWITCH on back of unit to energize brewer Water Inlet Solenoid will energize filling the ta...

Страница 9: ...e brew chambers are clean Check that the bypass diverters are properly installed in the brew chambers START UP Press POWER SWITCH back of brewer to ON Brewer water tank will begin filling When tank stops filling press HEATER ON OFF switch to ON READY TO BREW light will glow when water is at proper temperature for brewing Press SATELLITE WARMER switches to OFF until ready to begin brewing OPERATING...

Страница 10: ...il it is fully seated Press appropriate WARMER SWITCH to ON Select Brew Volume Press VOLUME SELECT switch to 1 GAL or 1 1 2 GAL Start the Brew Press either the right or left START BREW key NOTE The brew can be cancelled at any time by pressing the BREW STOP key At the end of the brew be sure all water has stopped dripping before removing the brew chamber When the READY TO BREW light comes on the b...

Страница 11: ... the brew basket but is diverted from the grounds by a bypass channel The remainder of the brew water is discharged through the SPRAY DISK and flows over the grounds in the brew basket Each half of the brewer is independently controlled HOT WATER FAUCET The HOT WATER FAUCET is fed by gravity from the hot water tank The faucet is spring loaded closed and manually opened The 9221 Series of brewers h...

Страница 12: ...sed to clean around the bypass diverters Rinse with clean water and allow to air dry Be sure bypass diverters are properly installed 8 Remove and drain the drip tray Rinse in a sink under warm running water Allow to air dry then reinstall on brewer 9 Wipe exterior of brewer and satellites with a soft clean cloth or sponge moistened with clean water 10 Reinstall gaskets INSIDE brew heads and then r...

Страница 13: ...ve sight glass tube from silicone elbow Run the sight glass brush through the tube at least ten times c Reassemble the tube to the silicone elbow Be sure the elbow has not been pulled from the satellite body d Reinstall the sight glass guard 6 Reinstall lids Install satellites on brewer 7 Rinse satellites With an empty brew chamber in place press the BREW key and run 1 full cycle into each satelli...

Страница 14: ... lid assembly Do not disconnect the tank assembly at this time 3 Siphon all water from the hot water tank 4 Mix 10 gallons of deliming solution according to the manufacturer s directions Carefully pour the deliming solution into the water tank Lower the lid assembly back onto the tank Allow to sit for 30 minutes or as directed by the chemical manufacturer 5 At end of soaking period reconnect brewe...

Страница 15: ...an water Reinstall one empty satellite under each brew chamber Brewer is ready to use DRAINING HOT WATER TANK 1 Disconnect brewer from the electrical supply 2 Remove the top panel assembly 4 Screws 3 Remove the front panel assyembly 4 Screws 4 Release the drain hose hose clamp assy from the retaining clip 5 Bring the drain hose down out the front panel so its lower than the tank 6 Remove the red h...

Страница 16: ...N OFF switch to OFF Turn POWER switch on back of brewer OFF 2 Remove TOP PANEL Operating controls are accessible through the top panel only 3 Adjust the TIMER setting NOTE Each side has its own timer The LEFT TIMER is for the LEFT SIDE the RIGHT TIMER is for the RIGHT SIDE Turn CLOCKWISE to increase time Turn COUNTER CLOCKWISE to decrease time Adjust only in small increments to avoid large volume ...

Страница 17: ...ead screwdriver Satellite or other container to calibrate volume 1 Press HEATER ON OFF switch to OFF Turn POWER switch on back of brewer OFF 2 Remove TOP PANEL Operating controls are accessible through the top panel only 3 Remove one of the plugs in the tank cover and insert a thermometer of known accuracy 4 Locate the CONTROL THERMOSTAT on the right side of the top housing Turn CLOCKWISE to incre...

Страница 18: ...wrong filter used Use one genuine Bloomfield paper filter per brew Chamber discharge hole plugged Clean brew chamber Timer not set properly Set timer Too much coffee or too fine a grind Check with coffee supplier for recommended grind and quantity Heats slow Connected to wrong voltage Verify supply voltage Scale build up on heating elements De lime hot water tank Damaged heating element Replace el...

Страница 19: ...4313 1 HANDLE FAUCET GUARD 4 2U 76577 1 FAUCET SHANK ASY 4 1 2V Z15411 1 FAUCET ESP ULTEM HI TEMP 4 2 2U 71460 1 SEAT CUP TEA DISP FAUCET 4 4 2C 84393 1 HEX NUT SPOUT VALVE 4 5 2C H2016 1 WASHER C TOMLINSON 4 6 2A 84395 1 SHANK FAUCET 4 7 2U 84396 1 SHANK ASSY FAUCET 4 8 2C 84489 1 WASHER FIBER 4 9 2A 84488 1 FERRULE VALVE SHANK 5 D7 74539 1 ASSY SIGHT GAUGE HOUSING 6 D7 74300 1 BRKT SIGHT GAUGE 7...

Страница 20: ...IL2309 PL671 EXPLODED VIEW 9221 CABINET AND EXTERIOR COMPONENTS 18 671 2M Z16955 Owners Manual 9221 Dual Satellite Brewer ...

Страница 21: ...NK SUPPORT TOP 19 2E 74620 2 SWITCH LIGHTED SP OFF MOM 20 2E 74621 2 SWITCH DP ON MOM OFF 10A 21 2C 73457 25 NUT 8 32 HEX HEAD KEPS MS 22 2E 74622 2 SWITCH DP ON NONE ON 10A 23 2E 72395 1 SWITCH ROCKER 250V 20AAM 24 2E 74098 1 SWITCH 2 POLE 50A 50 60HZ 25 D7 76573 1 HOUSING LOWER 26 D7 76589 1 COVER TOP HOUSING 27 D7 76587 1 PANEL FRONT 28 D7 76584 1 PLATE BOTTOM ASSY 29 D7 Z16271 1 BASE WRAP 30 2...

Страница 22: ...EXPLODED VIEW 9221 INTERIOR COMPONENTS 20 671 2M Z16955 Owners Manual 9221 Dual Satellite Brewer IL2310 PL671 ...

Страница 23: ...ATER 14 2A 74343 1 TUBE FILL 90 DEGREE 15 2T 73312 1 THERMO HI LIMIT DBL POLE 16 D7 76586 2 TANK LID ASSY 17 D7 74630 2 TUBE SIL 50 ID X 4 25 18 2K 70103 2 ELBOW OUTLET 19 2A 73384 4 TUBE SPRAY HEAD 2 3 8 LG 20 A6 73537 1 TUBE SIL 312 ID X 9 LG 21 2V 73388 2 VALVE ADJUST WATER OUTLET 22 2C 72148 1 WASHER LOCK 1 2 ID INT SE 23 2C 35485 1 NUT 1 4 20 HEX FINISHD SS 24 2C 76007 4 SCREW 8AX1 2 SS TR PH...

Страница 24: ...ENTS 22 671 2M Z16955 Owners Manual 9121 9221 Dual Satellite Brewer SK2651 Rev 5 8 13 Model 9121 Single Satellite Brewer 1 3 4 5 6 7 8 2 9 10 12 11 13 14 15 16 17 18 32 33 34 35 1 1 31 30 23 24 22 See Detail A 21 19 20 29 28 27 26 25 36 37 38 39 40 ...

Страница 25: ...2E 74621 1 SWITCH DP ON MOM OFF 10A 18 2E 74620 1 SWITCH LIGHTED SP OFF MOM 19 D7 Z17065 1 BRKT TERMINAL BLOCK 20 2E 37465 1 TERM BLOCK 3POLE 85AMP 21 2C 46672 1 LUG GROUND SOLDERLESS 6 1 22 2E Z14960 1 CONTACTOR 40A 23 Z1 70 07 0343 1 SWITCH GUARD 24 2E 30330 1 SWITCH ON OFF TOGGLE 20A 25 2A 73098 4 LEG 4 BLK PLASTIC W FLAN 26 2Q 75089 1 DOOR ACCESS PLASTIC 27 2V 74427 1 SOLENOID SINGLE 120V 1 0 ...

Страница 26: ...IEW CABINET AND EXTERIOR COMPONENTS 24 671 2M Z16955 Owners Manual 9121 9221 Dual Satellite Brewer SK2652 Rev 5 8 13 Model 9121 Single Satellite Brewer Tank Assy 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 14 Detail A ...

Страница 27: ...POLE 5 2C 73415 2 NUT 6 32 HEX 1 00 LG ALUM 6 A6 73521 1 PROBE ASSY WATER LEVEL 120 240V 230V L2 75976 PROBE ASSY WATER LEVEL 1 61 120V 7 2A 73532 1 SLEEVE WATER LEVEL PROBE 8 D7 WL0347 1 TANK COVER ASSY 9 2K 70103 1 ELBOW OUTLET 10 2A 73384 1 TUBE SPRAY HEAD 2 3 8 LG 11 2I Z16545 1 TANK GASKET 12 2N 76571UL 1 ELEM HEATIN 120V 1500W HW 120V 2 120 240V 230V 13 2C 43914 1 TIE WIRE MTG STUD M4200 2 1...

Страница 28: ...OAD 1 L2 LINE 1 LINE 2 T1 BLACK L1 2 3 4 RED L2 WHITE N HI LIMIT THERMOSTAT TERMINAL BLOCK HTG ELEMENT LEFT 208V 2750W 240V 3000W SWITCH POWER INLET VALVE BOARD LIQUID LEVEL THERMOSTAT LEFT TIMER BREW LIGHT HEATER SWITCH R STOP BREW SWITCH R VOLUME SELECT SWITCH 21 BLACK 23 BLACK 23 BLUE 26 BLUE 28 WHITE 20 7 1 BLACK 12 GA BROWN 12 GA 2 BLUE ORANGE BLACK 17 21 21 22 23 R START BREW SWITCH L VOLUME...

Страница 29: ...2 WHITE N HI LIMIT THERMOSTAT TERMINAL BLOCK HTG ELEMENT LEFT 120V 1500W SWITCH POWER INLET VALVE BOARD LIQUID LEVEL THERMOSTAT BREW LIGHT HEATER SWITCH STOP BREW SWITCH VOLUME SELECT SWITCH 21 23 26 28 7 1 2 21 21 START BREW SWITCH 24 27 RED YELLOW 23 3 L2 L1 T2 T1 1 1 2G 1G L1 WIRE L2 LOAD TIMER INPUT NO COM MAX NC 18 11 TANK GROUND 33 JUMPER 50 60 13 7 3150 120 240 9121 HZ MODEL AMPS WATTS VOLT...

Страница 30: ...ST HI LIMIT SWITCH HI LIMIT SWITCH HEATER SWITCH HEATER SWITCH BREW LIGHT THERMOSTAT INLET VALVE DUMP VALVE 230V N LIQUID LEVEL PROBE BOARD LIQUID LEVEL TANK GROUND HTG ELEMENT LEFT 120V 1500W HTG ELEMENT RIGHT 120V 1500W START BREW SWITCH MOM NO L1 WIRE L2 LOAD TIMER RED YELLOW VOLUME SELECT SWITCH 1 1 2G 1G 2M Z17228 REV 50 60 13 7 3150 230 9121 HZ MODEL AMPS WATTS VOLTS 50 60 13 3 3050 230 8795...

Страница 31: ...NOTES 29 671 2M Z16955 Owners Manual 9121 9221 Dual Satellite Brewer ...

Страница 32: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www wellsbloomfield com ...

Отзывы: