PROCEDURE: Clean Satellite
PRECAUTIONS: Drain Satellite before Cleaning
FREQUENCY: Twice Weekly
TOOLS:
Sight Glass Brush, Sanitizer
Soft Clean Cloth, Bucket
1. Remove and drain satellites. Remove lids.
2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap
water. Pour approximately 1 gallon of sanitizer solution into
each satellite. Allow to stand for 2 minutes.
3. Drain sanitizer solution from satellite into the bucket.
4. Disassemble faucet. Brush clean with sanitizer solution.
Reassemble faucet.
5. If necessary, disassemble and clean sight glass.
a. Push down on ears on sight glass guard . Then, pull
ears forward. Lift guard off of retaining clip.
b. Remove sight glass tube from silicone elbow. Run the
sight glass brush through the tube at least ten times.
c. Reassemble the tube to the silicone elbow. Be sure the
elbow has not been pulled from the satellite body.
d. Reinstall the sight glass guard.
6. Reinstall lids. Install satellites on brewer.
7. Rinse satellites: With an empty brew chamber in place,
press the BREW key and run 1 full cycle into each satellite.
8. Drain water from satellites.
Procedure is complete
CAUTION:
BURN HAZARD
Brewing and serving
temperatures of coffee
are extremely hot.
Hot coffee will cause
serious skin burns.
IMPORTANT:
DO NOT submerge satellite in
water.
IMPORTANT:
DO NOT use steel wool, sharp
objects, or caustic, abrasive or
chlorinated cleansers to clean
the satellites.
Sight Glass
11
CLEANING INSTRUCTIONS (continued)
671 2M-Z16955 Owners Manual 9221 Dual Satellite Brewer
671 2M-Z16955 Owners Manual 9221 Dual Satellite Brewer
IL2308
Содержание 9121
Страница 22: ...EXPLODED VIEW 9221 INTERIOR COMPONENTS 20 671 2M Z16955 Owners Manual 9221 Dual Satellite Brewer IL2310 PL671 ...
Страница 31: ...NOTES 29 671 2M Z16955 Owners Manual 9121 9221 Dual Satellite Brewer ...
Страница 32: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www wellsbloomfield com ...