OPERATION (continued)
7
A. START-UP
For initial start-up, or if the brewer has not been used for an
extended period of time:
♦
Be sure spray disk and brew gasket are properly installed in the
brew head.
♦
Be sure the water supply is properly connected and the water
supply valve is turned
ON
.
♦
Be sure the WATER TANK IS FILLED.
IMPORTANT:
Fill the water tank before energizing this unit:
1.
Insert the "COFFEE" brew chamber (empty) and place an empty
container in place under the brew chamber.
2.
Be sure the TANK HEATER SWITCH on back of brewer "
OFF
".
3.
Plug the unit into an appropriate receptacle.
4.
Press COFFEE/TEA switch to "COFFEE". Press BREW SWITCH.
Water will begin filling the tank. When the water fill stops, press the
switch again. Repeat until water flows from the brew chamber.
This will usually require running three (3) cycles.
5.
When water starts to flow from the brew chamber, tank is full.
When all dripping has stopped, discard all water in container.
6. Turn TANK HEAT SWITCH "
ON
". The heating elements will begin
heating the water in the tank. When the water has reached the
proper temperature, the “
READY TO BREW”
light will glow.
B. OPERATIONAL NOTES
1. COFFEE
a. When brewing coffee, be sure to use the "coffee" brew
chamber (uses the tall rack, and does
not
state "tea only" on
the outside of the shell).
b. Press the COFFEE/TEA switch to "
COFFEE
".
c. COFFEE MODE will brew 64 oz. of coffee.
d. Use a standard 64 oz. decanter.
2. TEA
a. When brewing tea, be sure to use the "tea" brew chamber
(uses the short rack, and states "tea only" on the outside of the
shell).
b. Press the COFFEE/TEA switch to "
TEA
".
c. Select either "1 gallon" or "3 gallon brew".
d. Use a dispenser of the appropriate size. Be sure dispenser is
positioned so that water from the BYPASS NOZZLE flows into
the dispenser.
IMPORTANT:
Tank must be full of water
before tank heater switch
"
ON
". Heating element
will be damaged if allowed
to operate without being
fully submerged in water.
Damage caused by
operating the brewer
without water in the tank
is
NOT COVERED BY
WARRANTY
.
NOTE:
After tank is filled, turn the
tank heater switch "on".
Brewer will require
approximately 18 minutes
to heat water to operating
temperature.
M6
28
76
20
1
Ow
n
e
rs
M
a
nu
al
8
7
8
1
A
Tea
Br
ew
e
r
Содержание 8781A
Страница 4: ...FEATURES AND OPERATING CONTROLS 2 M628 76201 Owners Manual 8781A Tea Brewer...
Страница 8: ...OPERATION Fig 3 Brewer Operation Diagram 6 M628 76201 Owners Manual 8781A Tea Brewer...
Страница 22: ...8781A EXPLODED VIEWS PARTS LIST 20 M628 76201 Owners Manual 8781A Tea Brewer...
Страница 23: ...8781A EXPLODED VIEWS PARTS LIST continued 21 M628 76201 Owners Manual 8781A Tea Brewer...
Страница 25: ...8781A WIRING DIAGRAM 23 M628 76201 Owners Manual 8781A Tea Brewer...