background image

MODEL 

VOLTS 

1ø 

WATTS 

AMPS 

1ø 

POWER SUPPLY 

CORD 

8781A 

120 VAC  

1500 W 

12.5 A 

6' with NEMA 5-15P 

TABLE OF CONTENTS 

SPECIFICATIONS 

Thank You for purchasing this 
Bloomfield Industries appliance. 
 
Proper installation, professional 
operation and consistent 
maintenance of this appliance will 
ensure that it gives you the very 
best  performance  and  a  long, 
economical service life.  
 
This manual contains the 
information needed to properly 
install this appliance, and to use, 
care for and maintain or repair the 
appliance in a manner which will 
ensure its optimum performance. 

WARRANTY STATEMENT                                  xi 
SPECIFICATIONS                                                  1 
FEATURES & OPERATING CONTROLS            2 
PRECAUTIONS & GENERAL INFORMATION    3 
AGENCY LISTING INFORMATION                      3 
INSTALLATION INSTRUCTIONS                         4 
OPERATION                                                            6 
BREWING COFFEE                                              9 
BREWING TEA                                                     10 
CLEANING INSTRUCTIONS                              11   
TROUBLESHOOTING SUGGESTIONS             12 
SERVICING INSTRUCTIONS                            14 
           Deliming Instructions                                19 
EXPLODED VIEW & PARTS LIST                     20 
SERVICE KITS                                                     22 
WIRING DIAGRAMS                                            23 

APPLICABILITY 

This manual applies to the following Bloomfield Industries products: 

 
8781A 

M6

28

 76

20

1   

Ow

n

e

rs

 M

a

nu

al

 8

7

8

1

Tea 

Br

ew

e

Содержание 8781A

Страница 1: ...05 cps 628 OWNERS MANUAL for AUTOMATIC COFFEE TEA BREWERS MODEL 8781A Includes Installation Operation Use Care Servicing Instructions Model 8781A Brewer with optional 8799 3 gallon Iced Tea Dispenser...

Страница 2: ...s parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS F...

Страница 3: ...this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PREC...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 5: ...e is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and under...

Страница 6: ...etween 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoi...

Страница 7: ...proper circuit and receptacle NSF requires that the brewer be able to be moved for cleaning underneath Loops of copper tubing will satisfy this requirement See Figure 2 below In some areas local codes...

Страница 8: ...OPERATION Fig 3 Brewer Operation Diagram 6 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 9: ...will begin heating the water in the tank When the water has reached the proper temperature the READY TO BREW light will glow B OPERATIONAL NOTES 1 COFFEE a When brewing coffee be sure to use the coff...

Страница 10: ...sending cold dilution water from an external source to the dispenser Water flowing into the tank forces a like amount of heated water out of the tank to perform the brew POUR OVER OPTION If an externa...

Страница 11: ...ter under the brew chamber When the flow and all dripping stops at the end of the brew cycle the coffee is ready to serve Discard the contents of the brew chamber and rinse it in a sink When the READY...

Страница 12: ...ad where it will spray over the bed of grounds Freshly brewed coffee will begin to fill the dispenser Additionally a measured amount of cold dilution water will flow from the bypass nozzle into the di...

Страница 13: ...sink using warm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 Wipe the exterior of the brewer with a soft clean cloth or spo...

Страница 14: ...Too many filter papers or wrong filter paper Use one 1 genuine Bloomfield filter per brew Brew chamber dispense hole plugged Thoroughly clean brew chamber Wire rack not in place Install proper wire ra...

Страница 15: ...of coffee per brew Freshly ground coffee beans make the best coffee beverage Be sure to use the coffee brew chamber with the tall wire rack Poor tea quality Keep brewer brew chamber and dispenser cle...

Страница 16: ...tubing faucet valve and piping and switches Top panel is held by two screws at the rear and a retaining lip at the front FRONT PANEL Remove front panel to access timer wiring and bypass nozzle plumbi...

Страница 17: ...ied technical personnel only NOTE Optimum brewing temperature is 195 F to 205 F 90 C to 96 C Thermostat should be adjusted to a maximum temperature of 200 F 95 C IMPORTANT A mechanical thermostatwill...

Страница 18: ...Run several cycles to check amount of water delivered Replace button plug REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF Turn OFF water supply Remove top panel Disconnect brew fil...

Страница 19: ...will not flow water Unplug power cord or turn circuit breaker OFF Turn OFF and disconnect water supply from brewer inlet fitting Unscrew water inlet fitting from solenoid Using needle nose pliers with...

Страница 20: ...erse order REPLACE CONTROL PANEL LIGHT or SWITCH Unplug power cord or turn circuit breaker OFF Using Switch Removal Tool p n 83209 to remove TEA VOLUME SELECT BREW SWITCH or STOP BREW switch Use a thi...

Страница 21: ...nk lid assembly as described on page 13 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming s...

Страница 22: ...8781A EXPLODED VIEWS PARTS LIST 20 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 23: ...8781A EXPLODED VIEWS PARTS LIST continued 21 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 24: ...erator Disk Aerator Cap 84870 Aerator Repair Kit Includes O Ring Aerator Disk SOLENOID REPAIR KITS 73282 Solenoid Complete Dual 60 gpm 19 gpm 75685 Solenoid Complete 75 gpm with Bypass 85218 Inlet Fit...

Страница 25: ...8781A WIRING DIAGRAM 23 M628 76201 Owners Manual 8781A Tea Brewer...