background image

NOTE:  

For your protection, please note that equipment in 

this shipment was carefully inspected and packaged by 
skilled personnel before leaving the factory.   
Upon acceptance of this shipment, the transportation       
company assumes full responsibility for its safe delivery.

 

IF SHIPMENT ARRIVES DAMAGED:

 

1.

      VISIBLE LOSS OR DAMAGE:

    Be  certain  that  any 

         visible  loss  or  damage  is  noted  on  the  freight  bill  
         or express receipt, and that the note of loss or damage 
         is signed by the delivery person. 
2.     

FILE CLAIM FOR DAMAGE IMMEDIATELY: 

 

         Regardless of the extent of the damage. 

3.

CONCEALED LOSS OR DAMAGE: 

 if damage is 

        unnoticed until the merchandise is unpacked, notify the           
        transportation company or carrier immediately, and file    
        “CONCEALED DAMAGE” claim with them.  This 
        must be done within fifteen (15) days from the date the  
        delivery was made to you.  Be sure to retain the 
        container for inspection. 

 

Bloomfield Industries cannot assume liability for damage or 
loss incurred in transit.  We will, however, at your request, 
supply you with the necessary documents to support your 
claim. 

WARRANTY STATEMENT 

SERVICE POLICY AND PROCEDURE GUIDE 

ADDITIONAL WARRANTY EXCLUSIONS 

SHIPPING DAMAGE CLAIMS PROCEDURE 

1.     Resetting   of  safety  thermostats,  circuit breakers,  
         overload  protectors,  or  fuse  replacements  unless       
         warranted conditions are the cause. 
2.     All problems due to operation at voltages other than 
         specified  on  equipment  nameplates;  conversion  to     
         correct voltage must be the customer’s responsibility. 
3.     All problems due to electrical connections not made in 
        accordance  with  electrical  code  requirements  and  
         wiring diagrams supplied with the equipment. 
4.     Replacement of items subject to normal wear, to include 
         such items as knobs and light bulbs.  Normal maintenance 
          functions  including  adjustment  of  thermostats,  microswitches, 
          and replacement of fuses and indicating lights are not 
         covered under warranty. 
5.     All problems due to inadequate water supply, such as 
         fluctuating, or high or low water pressure. 
6.      All  problems  due  to  mineral/calcium  deposits,  or        
         contamination  from  chlorides/chlorines.  De-liming  is   
         considered  a  preventative  maintenance  function  and  is 
         not covered by warranty. 

All electrical equipment manufactured by BLOOMFIELD 

 

 

 

INDUSTRIES is warranted against defects in materials and 
workmanship for a period of one year from the date of original 
installation or eighteen (18) months from the date of shipment 
from our factory, whichever comes first, and is for the benefit 
of the original purchaser, except that: 
a.     airpots carry a 30 day parts warranty only. 
b.

dispensers; i.e., tea and coffee carry a 90  days parts      

        warranty only, excludes decanters. 

 
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN 
LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR 
IMPLIED,  INCLUDING  ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE, WHICH ARE HEREBY EXCLUDED.   
 
BLOOMFIELD  INDUSTRIES  DIVISION  /  SPECIALTY  
EQUIPMENT MANUFACTURING CORPORATION SHALL 
NOT  BE  LIABLE  FOR  INDIRECT,   INCIDENTAL  OR 
CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY 
CAUSE WHATSOEVER. 

 
This warranty is void if it is determined that upon inspection by 
an Authorized Service Agency that the equipment has been 
modified,  misused,  misapplied,  improperly  installed,  or     
damaged in transit or by fire, flood or act of God. 

It also does not apply if the serial nameplate has been       
removed or unauthorized service personnel perform service.  
The prices charged by Bloomfield Industries for its products 
are based upon the limitations in this warranty.  Seller’s     
obligation under this warranty is limited to the repair of defects 
without charge by a Bloomfield Industries Authorized Service 
Agency or one of its sub-agencies.  This service will be     
provided on customer’s premises for non-portable models.  
Portable models (a device with a cord and plug) must be 
taken or shipped to the closest Authorized Service Agency, 
transportation charges prepaid, for services. 

 
In addition to restrictions contained in this warranty, specific 
limitations are shown below (Additional Warranty Exclusions).  
Bloomfield Industries Authorized Service Agencies are located 
in principal cities. 

 
This warranty is valid in the United States and void elsewhere.  
Please consult your classified telephone directory or your food 
service equipment dealer; or, for information and other details 
concerning warranty, write to: 

 

Service Parts Department 

Bloomfield Industries 

P.O. Box 280 

Verdi, NV  89439 

Phone:  (888) 492-2782          Fax: (888) 492-2783

 

  7.   Full use, care and maintenance instructions are supplied 
         with  each  machine.    Those  miscellaneous  adjustments 
         noted  are  customer  responsibility.    Proper  attention  will 
         prolong the life of the machine. 
  8.  Travel  mileage is limited to  sixty (60)  miles from an   
         authorized Service Agency or one of its sub-agencies. 
  9.   All labor shall be performed during normal working hours.  
         Overtime premium shall be charged to the customer. 
10.   All genuine Bloomfield replacement parts are warranted 
 

       for ninety (90) days from date of purchase on non-

         warranted  equipment.   

Any use of non-genuine 

 

         Bloomfield parts completely voids any warranty

11.  Installation, labor and job check-out are not considered 
         warranty. 
12.  Charges incurred by delays, waiting time or operating 
         restrictions  that  hinder  the  service  technicians  ability  
        to  perform services  are  not  covered  by  warranty.  
         This  includes  institutional and correctional facilities. 

xi 

M62

8

 76
201

   

Ow

ner

s M

a

n

u

a

l 87
81
A Tea

 B

re

w

e

Содержание 8781A

Страница 1: ...05 cps 628 OWNERS MANUAL for AUTOMATIC COFFEE TEA BREWERS MODEL 8781A Includes Installation Operation Use Care Servicing Instructions Model 8781A Brewer with optional 8799 3 gallon Iced Tea Dispenser...

Страница 2: ...s parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS F...

Страница 3: ...this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PREC...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 5: ...e is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and under...

Страница 6: ...etween 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoi...

Страница 7: ...proper circuit and receptacle NSF requires that the brewer be able to be moved for cleaning underneath Loops of copper tubing will satisfy this requirement See Figure 2 below In some areas local codes...

Страница 8: ...OPERATION Fig 3 Brewer Operation Diagram 6 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 9: ...will begin heating the water in the tank When the water has reached the proper temperature the READY TO BREW light will glow B OPERATIONAL NOTES 1 COFFEE a When brewing coffee be sure to use the coff...

Страница 10: ...sending cold dilution water from an external source to the dispenser Water flowing into the tank forces a like amount of heated water out of the tank to perform the brew POUR OVER OPTION If an externa...

Страница 11: ...ter under the brew chamber When the flow and all dripping stops at the end of the brew cycle the coffee is ready to serve Discard the contents of the brew chamber and rinse it in a sink When the READY...

Страница 12: ...ad where it will spray over the bed of grounds Freshly brewed coffee will begin to fill the dispenser Additionally a measured amount of cold dilution water will flow from the bypass nozzle into the di...

Страница 13: ...sink using warm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 Wipe the exterior of the brewer with a soft clean cloth or spo...

Страница 14: ...Too many filter papers or wrong filter paper Use one 1 genuine Bloomfield filter per brew Brew chamber dispense hole plugged Thoroughly clean brew chamber Wire rack not in place Install proper wire ra...

Страница 15: ...of coffee per brew Freshly ground coffee beans make the best coffee beverage Be sure to use the coffee brew chamber with the tall wire rack Poor tea quality Keep brewer brew chamber and dispenser cle...

Страница 16: ...tubing faucet valve and piping and switches Top panel is held by two screws at the rear and a retaining lip at the front FRONT PANEL Remove front panel to access timer wiring and bypass nozzle plumbi...

Страница 17: ...ied technical personnel only NOTE Optimum brewing temperature is 195 F to 205 F 90 C to 96 C Thermostat should be adjusted to a maximum temperature of 200 F 95 C IMPORTANT A mechanical thermostatwill...

Страница 18: ...Run several cycles to check amount of water delivered Replace button plug REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF Turn OFF water supply Remove top panel Disconnect brew fil...

Страница 19: ...will not flow water Unplug power cord or turn circuit breaker OFF Turn OFF and disconnect water supply from brewer inlet fitting Unscrew water inlet fitting from solenoid Using needle nose pliers with...

Страница 20: ...erse order REPLACE CONTROL PANEL LIGHT or SWITCH Unplug power cord or turn circuit breaker OFF Using Switch Removal Tool p n 83209 to remove TEA VOLUME SELECT BREW SWITCH or STOP BREW switch Use a thi...

Страница 21: ...nk lid assembly as described on page 13 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming s...

Страница 22: ...8781A EXPLODED VIEWS PARTS LIST 20 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 23: ...8781A EXPLODED VIEWS PARTS LIST continued 21 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 24: ...erator Disk Aerator Cap 84870 Aerator Repair Kit Includes O Ring Aerator Disk SOLENOID REPAIR KITS 73282 Solenoid Complete Dual 60 gpm 19 gpm 75685 Solenoid Complete 75 gpm with Bypass 85218 Inlet Fit...

Страница 25: ...8781A WIRING DIAGRAM 23 M628 76201 Owners Manual 8781A Tea Brewer...

Страница 26: ...ustries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 698 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only PRINTED IN UNITED STA...

Отзывы: