INSTALLATION INSTRUCTIONS (continued)
NOTE:
This equipment must
be installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING:
ELECTRIC SHOCK
HAzARD:
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT assume
a plumbing line will provide
such a ground. Electrical shock
will cause death or serious
injury.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
IMPORTANT:
Do not connect
brewer to electrical power until
you are ready to fill the tank.
See instructions at left.
IMPORTANT:
The ground
prong of the plug is part of a
system designed to protect
you from electrical shock in
the event of internal damage.
Never cut off the ground prong
nor twist a blade to fit an
existing receptacle. Contact a
licensed electrician to install the
proper circuit and receptacle.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
In some areas, local codes require a backflow preventer (check
valve) to be installed on the inlet water line. If a backflow
preventer is used, you must install a water hammer arrester in the
incoming line, between the backflow preventer and the brewer
inlet, as far away from the brewer as space will allow. This will
relieve the excessive back pressures that can cause faucet leaks
and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT:
Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Models 1883 and 1883CA
are equipped with a cord and plug.
They require a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire
plus ground, with NEMA 5-15R or 5-20R Receptacle).
IMPORTANT:
Fill the water tank before energizing this unit:
1. Insert the brew chamber (empty) and place an empty airpot
in place under the brew chamber.
2. Plug the unit into an appropriate receptacle.
3. Be sure the brewer is “off” (I.e. no LEDs are lit).
4. Press BREW key three (3) times.
5. Press CANCEL key once.
6. When water starts to flow from the brew chamber, press
POWER key once. Unit will begin heating water in
preparation for the first brew.
5
Fig. 2 Water Supply Installation
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN
IL2682
COPPER LOOPS OR
FLEX LINES
(PROVIDED BY
PLUMBER)
WATER INLET
FITTING
SOLENOID
STRAINER
WASHER
FLOW
WATER
SUPPLY
SHUT-OFF VALVE
(PROVIDED BY
PLUMBER)
IL2681
IL2680