Bloomfield 1883 Скачать руководство пользователя страница 6

643   2M-Z17088 Owners Manual 1883  E.B.C. Lo-Profile 

Airpot Brewer

643   2M-Z17088 Owners Manual 1883  E.B.C. Lo-Profile 

Airpot Brewer

643   2M-Z17088 Owners Manual 1883  E.B.C. Lo-Profile 

Airpot Brewer

643   2M-Z17088 Owners Manual 1883  E.B.C. Lo-Profile 

Airpot Brewer

INSTALLATION INSTRUCTIONS

READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

REFER TO EXPLODED VIEWS Pages 18 thru 20 for 

COMPONENT NAMES/NUMBERS

Unpack the unit.  Inspect all components for completeness and 

condition.  Ensure that all packing materials have been removed 

from the unit. 

Verify that the Spray Head Gasket and Spray Disk are properly 

installed.  

LEVELING THE UNIT

Verify that an adjustable leg is installed at each corner of the 

brewer, and that a rubber foot is installed on each leg.

Set Brewer in its operating location.  Level the Brewer.  A spirit 

level should be placed on the top of the unit, at the edge, as a 

guide when making level adjustments.

Level the unit from left to right and front to back by turning the  

adjustable feet.  Be sure all four feet touch the counter to prevent 

tipping.

PLUMBER’S INSTALLATION INSTRUCTIONS 

Brewer should be connected to a 

POTABLE WATER, COLD 

WATER

 line.  Flush water line before connecting to Brewer. 

DO NOT use a saddle valve with a self-piercing tap for the water 

line connection.  Such a tap can become restricted by waterline 

debris.  For systems that must use a saddle tap,  shut off the 

main water supply and drill a 3/16” (minimum) tap for the saddle     

connection, in order to insure an ample water supply.  Remember 

to flush the line prior to installing the saddle.

The brewer must be installed on a water line with average     

pressure between 20 PSI and 90 PSI.  If your water pressure   

exceeds 90 PSI at anytime, a pressure regulator must be

installed in the water supply  line to limit the pressure to not more 

than 90 PSI in order to avoid damage to lines and solenoid.

A water shut-off valve should be installed on the incoming water 

line in a convenient location (Use a low restriction type valve, 

such as a 1/4-turn ball valve, to avoid loss of water flow thru the 

valve.
The provided water line strainer must be installed in the supply 

line, between the shutoff valve and inlet fitting.  Note FLOW     

arrow marking on strainer body.

IMPORTANT:

To enable the installer to make 

a quality installation and to  

minimize installation time, the 

following suggestions and tests 

should be done before the 

actual unit installation is started:

CAUTION:

 

EqUIPMENT DAMAGE

DO NOT plug in or energize this 

appliance until all Installation 

Instructions are read and 

followed.  Damage to the 

Brewer will occur if these 

instructions are not followed.

CAUTION: 

UNSTABLE          
EqUIPMENT HAzARD

It is very important for safety 

and for proper operation that the 

brewer is level and stable when 

standing in its final operating 

position.  Provided adjustable, 

non-skid legs must be installed 

at each corner of the unit.    

Failure to do so will result in 

movement of the brewer which 

can cause personal Injury and/

or damage to brewer.

NOTE:

  Water supply inlet line 

must meet certain minimum 

criteria to insure successful 

operation of the brewer.  

Bloomfield recommends 1/4” 

copper tubing for installation of 

less than 12 feet and 3/8” for 

more than 12 feet from a 1/2” 

water supply line.  

4

Содержание 1883

Страница 1: ...Z17088 Rev M643 131210 643 OWNERS MANUAL for E B C Electronic Brew Control LO PROFILE E B C AIRPOT BREWERS MODELS 1883 and 1883CA Includes Installation Use Care Servicing Instructions E B C brewers a...

Страница 2: ...ment 4 Replacement of items subject to normal wear to include such items as knobs and light bulbs Normal maintenance functions including adjustment of thermostats microswitches and replacement of fuse...

Страница 3: ...appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INS...

Страница 4: ...CONTROLS Fig 1 Features Operating Controls 2 CONTROL PANEL AIRPOT BREWER BREW HEAD BREW CHAMBER REMOVED CONTROL PANEL HOT WATER FAUCET BREW CHAMBER AIRPOT BREWING POSITION POWER CORD BREW NOZZLE SPRA...

Страница 5: ...n No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use li...

Страница 6: ...be installed on a water line with average pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit t...

Страница 7: ...w preventer check valve to be installed on the inlet water line If a backflow preventer is used you must install a water hammer arrester in the incoming line between the backflow preventer and the bre...

Страница 8: ...hamber 2 Plug the unit into an appropriate receptacle 3 Be sure the brewer is off I e no LEDs are lit 4 Press START key three 3 times 5 Press CANCEL key once 6 When water starts to flow from the brew...

Страница 9: ...lve allowing water from an external water supply to flow into the water tank The incoming water forces heated water out of the tank to perform the brew The solenoid uses a flow control device so that...

Страница 10: ...uring a brew may lower the temperature of the brew water A PREPARATION Place one 1 genuine Bloomfield paper filter in the brew chamber Add a pre measured amount of fresh coffee grounds Gently shake th...

Страница 11: ...ear clogged spray holes Rinse the spray disk with clean water and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may be used to clean the insi...

Страница 12: ...ine Bloomfield filter per brew Brew chamber dispense hole plugged Thoroughly clean brew chamber Too much coffee or too fine a grind Use correct grind and amount of coffee Sprays water from brew head S...

Страница 13: ...move top panel to access hot water tank thermo probe heating elements brew circuit tubing faucet valve and piping Top panel is held by two screws at the front and a retaining lip at the rear FRONT PAN...

Страница 14: ...r brewing temperature based on altitude Upon completion remove thermometer and reinstall the plug Fig 9 Checking and Adjusting Brew Temperature CAUTION Electric Shock Hazard These procedures involve e...

Страница 15: ...ck amount of water delivered Replace button plug In addition water delivered to the brew chamber will take a while to drip through as coffee Adjust the BREW SIGNAL TIMER dial on the controller to acco...

Страница 16: ...bly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes Reassemble in reverse order REPAIR HOT WATER FAUCET Remove top panel and turn faucet valve OFF Unscrew aerator c...

Страница 17: ...e keypad from body Remove all adhesive residue Remove protective backing from adhesive on new keypad Slide ribbon cable into slot on body from the outside then carefully apply keypad to face of body R...

Страница 18: ...ild Detergent Clean Soft Cloth or Sponge Bristle Brush Bottle Brush Large Sink or other appropriate work area 1 Unplug power cord Turn off the water shut off valve and disconnect the water supply line...

Страница 19: ...nd thermostat Reassemble piping for the faucet Verify that all internal components are dry then reinstall the top panel 9 Reconnect brewer to electrical supply and reconnect water supply 10 Install th...

Страница 20: ...Profile Airpot Brewer MODEL 1883 EXPLODED VIEW PARTS LIST 18 SK2700 Rev B 12 09 2013 Model 1883 Airpot Brewer 1 11 8 9 10 16 17 18 19 20 12 58 59 13 3 4 5 6 7 56 16 55 54 18 52 20 20 50 49 48 47 46 4...

Страница 21: ...ELBOW SPRAYER 28 A6 73538 1 TUBE SIL 312ID X 10 LG 29 2E Z17086 1 CONTROL BOARD 30 2M 73637 1 FACEPLATE CONTROL BOARD 31 2I 72215 1 GASKET SPRAYHEAD 32 A6 72727 1 SPRAY HEAD DISC EMBOSSED 33 2D 70234...

Страница 22: ...WS 82575 Seat Cup item 12c WS 82576 Faucet Repair Kit Includes 12a Handle 12c Seat Cup 12d Spring 12h Stem 12j Pin 12k Bonnet WS 82682 Retainer Clip item 12b WS 84804 Aerator Replacement Kit Includes...

Страница 23: ...ners Manual 1883 E B C Lo Profile Airpot Brewer 643 2M Z17088 Owners Manual 1883 E B C Lo Profile Airpot Brewer WIRING DIAGRAM 21 E B C LO PROFILE BREWER Model Volts Watts Amps 1883 120 1800 15 0 1883...

Страница 24: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www bloomfieldworldwide com...

Отзывы: