643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Profile
Airpot Brewer
,
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Profile
Airpot Brewer
,
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Profile
Airpot Brewer
,
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Profile
Airpot Brewer
,
TROUBLESHOOTING SUGGESTIONS
10
Symptoms
Possible Cause
Suggested Remedy
Water won’t heat
Brewer unplugged or circuit
breaker tripped
Check power supply cord, Check /
reset circuit breaker
Temperature setpoint too low
Set for desired temperature
Hi-Limit safety switch tripped
Allow to cool hi-limit will self-reset
Damaged internal component or
wiring
Examine wiring & connectors,
controller, power board and heating
element. Repair/replace as needed
Coffee level too high or low
Timer out of adjustment
Adjust controller
Brew chamber overflows
Too many filter papers or wrong
filter paper
Use one (1) genuine Bloomfield filter
per brew
Brew chamber dispense hole
plugged
Thoroughly clean brew chamber
Too much coffee or too fine a grind
Use correct grind and amount of
coffee
Sprays water from brew head Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
No brew (faucet flows OK)
Spray disk plugged
Clean spray disk
Damaged internal component or
wiring
Check keypad, controller, power
board & solenoid. Repair, replace as
needed
No brew plus no flow from
hot water faucet
Water supply OFF
Turn water supply ON
Solenoid inlet strainer plugged
Clean strainer
Water filter (if used) plugged
Replace filter element
No flow from hot water faucet Faucet valve turned OFF
Turn faucet valve ON
Poor coffee quality
Keep brewer and airpots clean.
Install a taste and odor filter in water supply, and replace cartridges
regularly.
Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.