"Main > Output > IP" Screen
The “Main > Output > IP” screen is a “read and write” screen to assign the IP parameters for the TS:
“Main > Output > IP” Screen
Destination IP: allows user to assign the IP address of the equipment to which the GigE output is streamed to.
Encapsulation: from the two available options (RTP & UDP) select the one that matches the protocol used by the
receiving equipment.
Destination Port: user must enter the IP Port of the receiving equipment. The factory default value is 50000. The range
is 1 to 65535. The port number assigned to each TS must be unique.
Source Port: user must enter the IP Port of the equipment that the input IP source is streamed from. The factory default
value is 50000. The range is 1 to 65535. The port number assigned to each TS must be unique.
NOTE: Port number is recommended to be from 49152 to 65535. Reason: Ports 1-1023 are
reserved and 1024-49151 are registered ports
Time to Live: is limit to the amount of time an IP packet can exist in an IP network. The value is set by the sender of the
packet, and reduced by every host on the route to packet’s final destination. If the Time to Live reaches zero before the
packet arrives at its final destination, then the packet is discarded. The purpose of this field is to avoid an undeliverable
packet from circulating on an IP network perpetually. The range is 1 to 255. Factory default value is 128.
Stuffing: Null packets are inserted to ensure that the TS bitrate assigned in 2 of Section 6.8.1 of 6270-2 User Manual
remains constant. Possible options are Enable and Disable. It is advisable to Disable stuffing when only GigE output is
used to help reduce the traffic on the network.
Output Enable: Allows operator to Enable/Disable IP output
1
2
3
4
6
5
7
The Destination IP Address must be present before streaming occurs, otherwise the session is aborted. For
Multicast applications, the IP address must be in the range 224.0.0.0 through 239.255.255.255. For Unicast
applications, the IP address must be outside the above mentioned range.
1
2
3
4
5
6
Remember to click on the SAVE button to apply the new values/configurations.
2
7