8 HDE-4S-PRO
Instruction Manual
INPUT POWER:
IEC 14 power inlet plug - rated 115/230 VAC; 2.0/1.0A; 60/50 Hz; equipped with Slo-Blo, 3.0 Amps, 250 V Fuse. 48
VDC power (optional) is provided on stk# 6372 48.
EAS CONTROL:
Terminal strip to activate the EAS messaging feature in one of two following ways:
a) 5-12 VDC between terminals 1 & 3 shown below
b) Dry Contact between terminals 2 & 3 shown below
1 2 3
GND
NOTE:
This feature is intended to activate EAS and override all input programs
with the EAS INPUT (see below for details). The QAM RF OUT (see below), ASI OUT (see 3 ) and DATA OUT
(see ) will all contain the EAS content on every program.
EAS INPUT:
RCA connectors for EAS Analog Audio (marked L & R) and Composite Video (marked VIDEO) inputs.
HD-SDI 1 - 4: +Spare input
BNC connectors to receive the HD-SDI inputs with loop-thru outputs for monitoring.
CC IN 1, 2, 3 & 4:
RCA connectors (marked “CC IN”) for Analog NTSC Closed Captioning (EIA-608, also known as Line 21), which will
then be digitized and inserted in the MPEG-2 Transport Stream of the Component inputs.
DATA OUT 1 GIGE:
RJ45 connector for GigE (1000Base-T Ethernet) interface for multiplexed SPTS or MPTS output streams. Only static IP
address can be assigned to this interface. The factory default value is 192.168.253.1.
REMOTE CONTROL 10/100:
RJ45 connector for 10/100Base-T Ethernet interface for monitoring and configuring the unit. Only static IP address can
be assigned to this interface. The factory default value is 172.16.70.1.
QAM RF OUTPUT:
“F” connector for up to four (4) QAM RF outputs.
IP RESET:
When pushed and held for about 10 seconds, resets the IP address, Usernames, and Passwords to Factory default
values as follows:
IP address = 172.16.70.1
Username = Admin (case-sensitive)
Password = pass (case-sensitive)
EAS FEATURE IS FUNCTIONAL ONLY WHEN (I) EAS CONTROL IS TRIGGERED ON, AND (II) VIDEO/AUDIO
IS DETECTED ON EAS INPUT CONNECTORS. THE EAS FEATURE WILL NOT BE FUNCTIONAL UNLESS BOTH
THESE CONDITIONS ARE MET.
5
6
7
9
8
7
12
3
10
12
11
10
13
9
5
6
7
13
12
8
10
11
-48 VDC Option
Stk# 6372 48