10
HDE-4S-PRO
Instruction Manual
Section 3 – Installation & Power-up
3.1 Unpacking
You will find the following items in the box:
• HDE-4S-PRO Encoder (QTY=1)
• Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)
• A hardware bag (item 741021800) containing the following:
Seven-foot cross-pinned (cross-over) RJ45 Ethernet cable (QTY=1)
3.2 Installation
The HDE-4S-PRO encoder is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN
41494 SC48D).
To install the encoder, secure the unit’s front panel to the rack by inserting four (4) machine screws, with cup washers,
through the four (4) mounting holes in the front panel.
3.3 Power-up
115/230 VAC Encoders (Stk# 6372):
Connect the line cord to a 110/230 VAC, 60/50 Hz outlet. Please note that the IEC power connector on the rear panel of the
unit is equipped with an ON/OFF switch and a fuse (SLO-BLO, 2.0 Amp, 250V). The “POWER” LED on the front-panel will light
green.
-48 VDC Encoders (Stk# 6372 48):
Connect the positive and negative leads from the batteries to the rear panel terminal strip.
FOR SAFE AND RELIABLE OPERATION, THE GROUND PIN OF THE POWER CORD PLUG
MUST BE GROUNDED PROPERLY.