STEP 4 - Main > Input Configuration
For the Input Configuration screen, DEMUX and PASS-THRU Modes allow 4 configurable Transport
Streams. MUX Mode allows up to 32 configurable Transport Streams (TS). Source selections for each
TS are: IP(UDP), IP(RTP), RF(optional), ASI#1 to ASI#4 and Disabled.
IP selections require Address and Port entries
RF (RFI option) channel setting is set under the QAM Config tab.
ASI #1 to #4 are the rear panel input connectors
Once all entries have been made click the “Save” button
1
2
3
1
2
3
The “RF Channel”
column will only
display when the
unit is installed
with RFI option.
When the unit is
not installed with
RFI option, the
“RF” source will
be greyed out.
The setting parameters are the same between DEMUX and MUX modes with the exception of the
number of Input and Output TS’. The DEMUX has (4) Input TS’ with up to (32) Output TS’ whereas the
MUX Mode is the complete opposite with (32) Input and (4) Output TS’s.
Select the desired programs from the Input TS’s under the green header (#1) for each output TS
(TS0#) using the “Selection Control” and click on the “Add =>” button.
To remove programs from the Output, click on the check box and then click the “<= Remove”
button.
DEMUX & MUX MODES ONLY
A
1
2
2
1
STEP 5 - Main > TS Map Settings
PASS-THRU MODE (
Not Available, go to Step 6
)
B