background image

16 AQT-RCS

Instruction Manual

Transferring Files to the AQT-RCS using FTP  

FTP — File Transfer Protocol is a commonly used protocol to transfer data from one computer to another over the Internet or a 
network that supports TCP/IP protocol. There are two computers or devices involved in an FTP transfer, a server and a client. The 
FTP server, running FTP server software, listens on the network for requests. The client, running FTP client software, initiates a 
connection to the server. Once connected the client can perform operations such as downloading or uploading files to the server. 
FTP servers by default listen on port 21 for incoming connections from FTP clients. The Blonder Tongue FTP site and the AQT-RCS 
act as FTP Servers.
• FTP client software, such as FTP Commander (a free FTP client software program) is required to access and transfer files to 
AQT-RCS unit. The appropriate username and password are required for transfer — default User Name: 'FTP' & Password: 'pass' 
(these entries are case sensitive)

 NOTE:  

FTP Commander Version 7.33 can be downloaded from the Blonder Tongue FTP Site, Version 8.x of the FTP 
Commander software does not function in some computer setup environments and thus, not recommended.

 

• Navigate to the Blonder Tongue FTP site @ ftp://ftp1.blondertongue.com/ftproot/

 

• The standard Internet Explorer web browser may be used to access and download the FTP Commander freeware

 

• Proceed to the FTP Commander directory and download the executable file

 

• Install the FTP Commander freeware software on your desired PC

The Firmware Upgrade process can not be cancelled or  
interrupted after proceeding. The upgrade process 
takes approximately 1 minute to complete.

The AQT-PCM LCD (if you are present at the headend to observe) will display 'PROGRAM FLASH' during the upgrade process. 
The Backlight of the LCD will shut off upon completion and the PCM will reboot itself. The bootload web utility will display the 
successful completion message when finished.

3.  Click

 Click Here to Download Boot File to PCM 

4.  Click 

OK

 on the confirmation message prompt.  

The updated firmware version number can now be verified on the Unit Info page of the AQT-RCS.

Verify the Firmware Version

Updating the AQT-RCS Web Pages

The AQT-RCS uses Java enabled http web pages for the interactive communication process. From time to time Blonder Tongue 
may make updated web pages available that address operational or bug related items as well as make new features available. The 
web pages should only be updated after consultation with the Blonder Tongue Technical Engineering Group.
 

The latest released web pages may be downloaded from the Blonder Tongue FTP site:  

 

ftp://ftp1.blondertongue.com/ftproot/AQTSeries/AQT_RCS/Web_pages/

It is recommended to always download and update all web pages in the FTP site directory when performing an update.
See the 'Transferring Files to the AQT-RCS using FTP' for additional instructions.

Updating the AQT-RCS Firmware

The AQT-RCS firmware may also be updated from time to time via FTP. The firmware file has a *.firm file format extension, the 
name of the file contains the actual version number of the firmware. 'AQTRCS

_101

.firm' indicates AQT

 

Server version 1.01. The 

firmware version can be verified by accessing the 'Setup' and/or "Admin" page — the last three digits indicate the firmware version. 
The firmware should only be updated after consultation with the Blonder Tongue Technical Engineering Group.

Verify the Firmware Version

Содержание AQT-RCS

Страница 1: ... 4000 FAX 732 679 4353 www blondertongue com 2008 Blonder Tongue Laboratories Inc All rights reserved Specifications are subject to change without notice Trademarks are the property of their respective owner AQT RCS AQT Remote Configuration Server Stock No 2736 651220600A M A D E I N U S A ...

Страница 2: ...SER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Unpacking and Installation NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s at ten tion to Article 820 40 of the NEC that provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close ...

Страница 3: ...tlet before cleaning Use only a damp cloth for cleaning the exterior of the unit Do not use accessories or attachments not recommended by Blonder Tongue as they may cause hazards and will void the warranty Do not operate the unit in high humidity areas or expose it to water or moisture Do not place the unit on an unstable cart stand tripod bracket or table The unit may fall causing serious persona...

Страница 4: ...surges Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits When installing an antenna take extreme care to avoid touching such power lines or circuits as contact with them can be fatal Do not overload wall outlets or extension cords as this can result in a risk of fire or electrical shock Never insert ...

Страница 5: ...xcept as otherwise expressly provided BT grants no express or implied right under BT patents copyrights trademarks or other intellectual property rights You may transfer the Software only if the recipient agrees to be fully bound by these terms and if you retain no copies of the Software EXCLUSION OF OTHER WARRANTIES EXCEPT AS PROVIDED ABOVE THE SOFTWARE IS PROVIDED AS IS WITHOUT ANY EXPRESS OR IM...

Страница 6: ...own below Operating System Any that supports Web Browser Interface Network Interface Card Any that supports Ethernet Protocol Web Browser Microsoft Internet Explorer 6 0 or later recommended JavaScript Enabled Required Display resolution 1024 x 768 recommended 800 x 600 required Processor Minimum Pentium III or equivalent recommended Memory Minimum 256 MB recommended Getting Started You will need ...

Страница 7: ...Static IP User Name Password Software Settable Administrator View Modes for Security Administration Mechanical Module Dimensions W x H x D 1 5 x 5 25 x 11 31 in 38 x 133 x 287 mm Chassis Dimensions W x H x D 19 x 5 25 x 12 in 483 x 133 x 305 mm Mounting W x H Standard 3 EIA Unit Height 19 x 5 25 in 483 x 133 mm Module Weight 1 5 lbs 68 kg General Power Requirement 5 VDC 200 mA Operating Temperatur...

Страница 8: ... 1 4 QAM RF OUT POWER DATA QAM RF OUT POWER DATA QAM RF OUT POWER DATA QAM RF OUT POWER DATA QAM RF OUT POWER DATA QAM RF OUT POWER DATA QAM RF OUT POWER DATA MODEL AQT PCM STOCK NO 6276 117V 2 0A 60 Hz FUSE 4 0A 250VDC SB S T A N D B Y I N D A T A O U T P O W E R I N P O W E R D A T A P O W E R D A T A MOD 5 8 MOD 1 4 QAM RF OUT 8VSB QAM INPUT ATSC QAM TRANSCODER MODEL AQT STOCK NO 6275 POWER DAT...

Страница 9: ...for a direct connection To Access the AQT RCS Open a web browser on your computer Enter the factory default IP address in the address line on your browser http 172 16 70 1 NOTE It may be necessary to adjust your computer s IP address settings to ensure that the same subnet address is set to permit first time communication to the AQT RCS Adjust your IP address from automatically obtain or another f...

Страница 10: ... Page and click Save to apply the information to non volatile memory Use the lower portion Headend Configuration to enter remove and verify AQT units The digital address of an AQT must be first entered into the AQT RCS before it can communicate The AQT digital address can be displayed by accessing the interactive menu using the UP DN arrow navigation keys on the front panel LCD menu of each PCM un...

Страница 11: ...aluable to ensure that the correct entry was made and that the wiring to the unit is correct Any unit installed can be checked at anytime or sequence in the process and it does not matter where the unit physically resides in the headend chain 1 Highlight a AQT address in the list by clicking on it 2 Click Check Unit to query the digital address highlighted The AQT RCS will attempt to communicate w...

Страница 12: ...ined by both the module lock status and the SNR status Headend Status Page Click to refresh update the page Click for Unit Info page Click for Setup page AQT PCM Address Unit Type Power Status Module Number Type Status Input Transponder Frequency Output Channel or Frequency Temperature Indication The Unit Information page provides detailed information for each AQT module connected to a respective ...

Страница 13: ...8 Volts 26 0 to 31 5 Output Channel or Frequency QAM State Output Level Input SNR Description Field Unit Information View Mode Unit Information Modify Mode Click for View Mode The AQT RCS Modify Mode page permits changes for each AQT module connected to the Power Control Module Individual module changes may only be made from this page with the Administrator logon Enter Input Frequency Enter Output...

Страница 14: ... for Administrative access and privileges Default Admin Password is pass The password field CAN NOT be left blank If it is left blank the unit must be reset using Temporary Hardware Admin Default Reset on page 15 View ID Case sensitive user identification for view only and privileges Default View ID is Guest View Password Case sensitive password for view only and privileges Default View Password i...

Страница 15: ... The unit should now be configured for the new Admin settings 8 To erase all entries and reset the unit to the factory default settings follow the Software Default Reset procedure 4 2 4 0 7 2 2 3 34 1 2 3 14 2 3 14 73 á NOTE After a hardware reset a direct connection to the AQT RCS may be required a cross Ethernet cable is required for a direct connection AQT RCS Utility Updating Tools NOTE Any AQ...

Страница 16: ... process takes approximately 1 minute to complete The AQT PCM LCD if you are present at the headend to observe will display PROGRAM FLASH during the upgrade process The Backlight of the LCD will shut off upon completion and the PCM will reboot itself The bootload web utility will display the successful completion message when finished 3 Click Click Here to Download Boot File to PCM 4 Click OK on t...

Страница 17: ...Updating the AQT RCS with BT FTP site files 1 Create a new directory on your local PC for the AQT RCS web pages and or firmware files required to update the unit 2 Download all the files from the Blonder Tongue FTP as instructed above to the new directory on your local PC 3 Click Disconnect to close the connection with the Blonder Tongue FTP Site and establish a connection with the AQT RCS unit cl...

Страница 18: ...18 AQT RCS Instruction Manual Notes ...

Страница 19: ...Z 7I a b iZY lVggVcin dg GZ jgW h ZY dg 8adhZdji EgdYjXih 6aa hVaZh d GZ jgW h ZY dg 8adhZdji EgdYjXih VgZ ÒcVa Id dWiV c hZgk XZ jcYZg i h lVggVcin i Z YZ ZXi kZ egdYjXi id Zi Zg l i V Xden d i Z hVaZh gZXZ ei dg di Zg hVi h VXidgn egdd d ejgX VhZ VcY V Wg Z YZhXg ei dc d i Z YZ ZXi bjhi WZ h eeZY gZ i egZeV Y id 7adcYZg Idc jZ AVWdgVidg Zh cX DcZ V Z 7gdlc GdVY DaY 7g Y Z CZl ZghZn I h lVggVcin ...

Страница 20: ...One Jake Brown Road Old Bridge NJ 08857 1000 USA 800 523 6049 732 679 4000 FAX 732 679 4353 www blondertongue com ...