6
HDE-8C DIN Series
Instruction Manual
FRONT PANEL:
-20dB QAM RF TEST:
“F” connector for RF testing @ -20dB below the main QAM RF output.
DATA OUT 1 GIGE (
QAM/IP Only
):
RJ45 connector for GigE (1000Base-T Ethernet) interface for SPTS or MPTS output
streams. Only static IP address can be assigned to this interface. (Factory Default: “192.168.252.1”)
STATUS LED:
LEDs indicate the status of the unit as follows:
Off:
Normal Operation
Blinking Red:
Overtemperature condition
Blinking Green:
EAS active
Blinking Red-Green:
Unit identification
POWER LED:
The power LED indicates the power of the unit as follows:
LED is Green
= AC power is detected.
LED is Off
= indicates (i) AC power is not connected, or (ii) AC power is connected but the power supply is defective.
The unit must be sent to Blonder Tongue for repair for condition (ii).
1
2
3
4
Description:
Unit front and rear panel connectors and indicators:
6
8
9
10
11
12
5
7
REAR PANEL:
INPUTS #1 thru 8:
Each DIN connector provides inputs for:
Component video:
Y, Pb, Pr
Closed Captioning (CC):
Analog NTSC (Composite video) EIA-608 which will then be inserted in the MPEG-2
transport stream.
L/R Analog Audio
Digital Audio
RECEIVERS CONTROL 10/100:
RJ45 connector for 10/100Base-T Ethernet interface for controlling satellite receivers.
QAM RF OUT:
“F” connector for up to four (4) QAM RF outputs.
IP RESET:
Push and hold for 5 seconds, to reset. Factory Defaults are as follows:
IP address = 172.16.70.1
Username = Admin (case-sensitive)
Password = pass (case-sensitive)