4
AP Series
Instruction Manual
Operating Controls - Front Panel
All operating controls and indicators for the processor are located on, or are accessible from the front panel.
1.
AURAL LEVEL
- Attenuates amplitude of aural RF carrier relative to visual RF carrier.
2.
OPERATING MODE SWITCH
- Positions 1, 2 & 3 used to select CATV or Broadcast mode.
3.
OFFSET SELECTOR
- Position 4 used to turn FCC Offset ON or OFF.
4.
OFFSET ADJUST
- Variable input frequency offset adjustment.
5.
INPUT CHANNEL SELECTOR
- Switches to select input channel.
6.
SELECTOR SWITCH
- Options
7.
EAS/ALT INDICATOR
- Lights green when EAS/ALT is active.
8.
INPUT CHANNEL LABEL
. - Attached by user for reference.
9.
OPERATING MODE SWITCH
- Positions 1, 2 & 3 used to select CATV or Broadcast mode.
10.
OFFSET SELECTOR
- Position 4 used to turn FCC Offset ON or OFF.
11.
OUTPUT CHANNEL SELECTOR
- Switches to select output channel in Standard, HRC, or IRC assignments and
broadcast.
12.
OUTPUT LEVEL
- Simultaneously adjusts amplitude of aural and visual carriers.
13.
POWER
- Power ON indicator light.
14.
OUTPUT CHANNEL LABEL
. - Attached by user for reference.
15.
CHANNEL SETTING EXAMPLES
- Channels 9 and 116 shown.
AP SERIES
AGILE PROCESSOR
POWER
STATUS
OUTPUT
LEVEL
LEVEL
AURAL
CH
1
2
3
5
6
10
11
12
9
13
15
7
4
8
,
EXAMPLES
CHANNEL
EAS
1
2
4
0 - 9
00 - 12
8
4
3
2
1
00
9
CH
=9
11
6
CH
=116
FOR SUB BAND INPUT
OPTION 17
CH T7 THRU CH T13
SET TO CH 7 THRU CH 13
1
2
4
8
OFF
ON
OFFSET
D3D2
SUM UP SW
D1
CATV
3
2
1
3
2
1
STD -
U
D
0
U U U
IRC - U D U
HRC -
BROADCAST -
U U D
U D D
EXAMPLES
CHANNEL
1
2
4
0 - 9
00 - 12
8
00
9
CH
=9
11
6
CH
=116
1
2
4
8
OFF
ON
OFFSET
D3D2
SUM UP SW
D1
CATV
3
2
1
3
2
1
STD -
U
D
0
U U U
IRC - U D U
HRC -
BROADCAST -
U U D
U
SUB BAND -
U U
D
D
D
T7 THRU CH T13
SET TO CH 7 THRU CH 13
CH
14
Front Panel View
CAUTION:
FOR CONTINUED
PROTECTION AGAINST
FIRE HAZARD, REPLACE
ONLY WITH SAME
TYPE 3/8A, 250V FUSE
RF OUT
AP40 - 550B 59802
SUB BAND OUT
ABOC
ON CH. LOCK
AP40 - 750B 59803
OPTIONS
STOCK
NO.
AGILE PROCESSOR
BLONDER TONGUE
LABORATORIES, INC.
RF IN
M A D E I N U S A
117V, 0.2A
60 Hz
3/8A SB
250V
LINE CORD
JUMPER
CABLE
RF
INPUT
RF OUTPUT
4
12
14
FUSE
IF
OUTPUT
IF INPUT
IF IN
IF OUT
EAS/ALT
IF INPUT
EAS/ALT
IF INPUT
MANUAL
AUTO
LISTED
UL
C
US
®
69SA
Rear Panel View - AP 40
CAUTION:
FOR CONTINUED
PROTECTION AGAINST
FIRE HAZARD, REPLACE
ONLY WITH SAME
TYPE 3/8A, 250V FUSE
RF OUT
AP60 - 550B 59817
SUB BAND OUT
ABOC
ON CH. LOCK
AP60 - 750B 59818
OPTIONS
STOCK
NO.
MODEL
AGILE PROCESSOR
BLONDER TONGUE
LABORATORIES, INC.
IF IN
IF OUT
EAS/ALT
IF INPUT
OFF
ON
RF IN
117V, 0.2A
60 Hz
3/8A SB
250V
SUB BAND
INPUT
CH T-7-T13
RF OUT
CH 7-13
4
12
14
SUB BAND IN
17
M A D E I N U S A
LINE CORD
RF OUTPUT
FUSE
JUMPER CABLE
RF INPUT
IF OUTPUT
IF INPUT
EAS/ALT
IF INPUT
SUB BAND IN
(OPTIONAL)
RF OUTPUT
MANUAL
AUTO
Rear Panel View - AP 60
Connections - Rear Panel
All connections to the unit are made at the rear panel.