8

AP Series 

Instruction Manual

Option 4 - Sub-Band Output

Description

Option 4 extends the output frequency range of an AP processor to include sub-band channels T7 through T13. 

This permits the unit to be used for sub-band via the return path in a two way system or as a LAN processor.  

All external controls and connectors remain the same as a standard model.  Video and Audio specifications for  

channels T7 through T13 also conform to standard processor performance.  RF specifications remain the same except 

for the following:

Specifications (Typical)

 

RF Output Frequency Range:  All Channels 7.0 - 550/750 MHz

SWITCH 2

8 4 2 1

Ones

Tens

8 4 2 1

7.0

13.0
19.0
25.0

31.0
37.0
43.0

Pix/MHz

T7

CH

T9

T10

T11 

T8

T12
T13 

INVOKED

REVOKED

Option 14 - ON CHANNELOCK

ON CHANNELOCK solves one of the commonly encountered problems of using an Agile Processor in the ON Channel 

Mode. (e.g. channel 9 VHF input, channel 9 VHF output).

The problem being addressed manifests itself as picture “flutter” similar to the effects of signals reflected from aircraft 

(although it is caused by a different phenomenon). The flutter most often occurs when the input signal is an off air 

antenna or antenna/preamplifier combination.
Option 14 is intended to be invoked only when the input is channel 2 - 13 broadcast and the output channel is the same 

as the input. Do not invoke Option 14 for conversions. Option 14 is invoked by Switch SW3, POSITION 1. Switch SW3, 

POSITION 1 is found in the bank of front panel accessible input channel selector switches. Place Switch SW3, POSITION 

1 down to invoke Option 14, up to disable Option 14. Also switch SW-1 POSITION 4 OFF when using Option 14.

As a reminder, turn “offset adjust” potentiometer fully clockwise when using this processor on the “ON Channel” mode 

regardless of whether the processor has Option 14 or not.
When setting up a processor for “ON Channel” operation be certain that the switches for the output selector are as 

required for “ON Channel” operation. Use the following procedure for best results when in the “ON Channel” mode and 

when using Option 14. 

1.   Switch SW-1 POSITION 4 is switched OFF when using Option 14 and ON to adjust for frequency offsets.
2.  Set Front Panel Offset Adjust Control fully clockwise.
3.  Switch SW-3, POSITION 1 is down to invoke Option 14 ON. Move to the up position for Option 14 OFF.

CHANNEL

LEVEL

AURAL

1

2

4

0 - 9

00 - 12

8

4

3

2

1

1

2

4

8

OFF

ON

OFFSET

SUM UP SW

CATV

3

2

1

3

2

1

STD -

U

D

0

U U U

IRC  - U D U

HRC -

BROADCAST -

U U D
U D D

Sw 1

Sw 3

Input Tuning

Содержание 59802

Страница 1: ...rtongue com 2004 Blonder Tongue Laboratories Inc All rights reserved Specifications are subject to change without notice Trademarks are the property of their respective owner AP Series Agile Processor with Emergency Alert System Model Stock No AP 40 550B 59802 AP 40 750B 59803 AP 60 550B 59817 AP 60 750B 59818 651204800C ...

Страница 2: ...ch is included to allow for an EXT IF input which can be used for EAS capability Options 04 Sub Band Output 12 Automatic Broadcast Offset Correction 14 On Channelock 17 Sub Band Input AP 60 xxx 20 Digital Control Serial RS 232 TTL Loop WARNING TOPREVENTFIREORSHOCKHAZARD DONOTEXPOSETHISUNITTORAINORMOISTURE NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s a...

Страница 3: ...l Passband Response fv to fv 4 5 MHz 1 dB at 0 dB A V adj fv 0 5 to fv 3 75 1 dB at any A V setting Adjacent Channel Rejection 65 dBc Equal Visual Car and 15 dB A V Ratio In Channel Carrier To Noise Ratio VHF Input 55 dB UHF Input 53 dB Broadband Noise 76 dBc Spurious output with A V 15 dB C V 17 dB In Channel 58 dBc Out of Channel 64 dBc 50 to 1 000 MHz Output Impedance On Channel 75 Ohm 14 dB Re...

Страница 4: ...FOR SUB BAND INPUT OPTION 17 CH T7 THRU CH T13 SET TO CH 7 THRU CH 13 1 2 4 8 OFF ON OFFSET D3D2 SUM UP SW D1 CATV 3 2 1 3 2 1 STD U D 0 U U U IRC U D U HRC BROADCAST U U D U D D EXAMPLES CHANNEL 1 2 4 0 9 00 12 8 00 9 CH 9 11 6 CH 116 1 2 4 8 OFF ON OFFSET D3D2 SUM UP SW D1 CATV 3 2 1 3 2 1 STD U D 0 U U U IRC U D U HRC BROADCAST U U D U SUB BAND U U D D D T7 THRU CH T13 SET TO CH 7 THRU CH 13 CH...

Страница 5: ...RMA Number is required on all products returned to Blonder Tongue regardless if the product is being returned for repair or credit Before returning product please contact the Blonder Tongue Service Department at 1 800 523 6049 Ext 4256 or visit our website www blondertongue com for further information PRECAUTIONS REQUIREMENTS Avoid Heat Buildup Allow 1 EIA rack space 13 4 between powered headend p...

Страница 6: ...vided into 2 sections the Tens section and the Ones section In each section there are 4 switches labeled 8 4 2 1 Each correspond to it s respective numeric value A simple chart shown below gives the corresponding switch positions for Tens position 1 to 12 and for the Ones position 0 9 The user sets the Tens section and the Ones section together to set the desired channel The artithmetic sum of the...

Страница 7: ...mmended ratio is 15 dB STANDBY CARRIER THRESHOLD The Standby Carrier Threshold is factory set for 19 dBmV If it is necessary to set the threshold to some other level pro ceed as follows before installing the AP Processor in its rack or cabinet 1 Plug the AP Processor power cord into a 117 VAC 60 Hz outlet The green Power LED on the front panel will light A warmup period of about 30 minutes is requ...

Страница 8: ... air antenna or antenna preamplifier combination Option 14 is intended to be invoked only when the input is channel 2 13 broadcast and the output channel is the same as the input Do not invoke Option 14 for conversions Option 14 is invoked by Switch SW3 POSITION 1 Switch SW3 POSITION 1 is found in the bank of front panel accessible input channel selector switches Place Switch SW3 POSITION 1 down t...

Страница 9: ...may use the frequency chart supplied with the product by following the settings for standard broadcast channels 7 13 as if they were T 7 through T 13 The sub channel converter has a conversion loss of approximately 8 dB Therefore a nominal input signal level to the sub band converter should be between 3 and 23 dBmV to ensure proper operation Connections for Sub Band Options 1 Set the Sub Band sele...

Страница 10: ... ABOC On Off position controls ABOC operation With the 4th switch UP the ABOC is activated and the output offset frequency will be maintained independent of the input offset It is recommended that the ABOC be kept on during Off Channel operation thus keeping the output offsets controlled During On Channel operation the ABOC should be switched off In this mode the output frequency will remain exact...

Страница 11: ...armonic Chan Video Video IRC Video HRC 63 457 2500 457 2625 456 64 463 2500 463 2625 462 65 469 2500 469 2625 468 66 475 2500 475 2625 474 67 481 2500 481 2625 480 68 487 2500 487 2625 486 69 493 2500 493 2625 492 70 499 2500 499 2625 498 71 505 2500 505 2625 504 72 511 2500 511 2625 510 73 517 2500 517 2625 516 74 523 2500 523 2625 522 75 529 2500 529 2625 528 76 535 2500 535 2625 534 77 541 2500...

Страница 12: ...ilable from BT on request VideoCipher DigiCipher are registered trademarks of Motorola Corp Rev 5 6 2009 Blonder Tongue Laboratories Inc Limited Warranty Blonder Tongue Laboratories Inc BT will at its sole option either repair or replace with a new or factory reconditioned product as BT may determine any product manufactured by BT which proves to be defective in materials or workmanship or fails t...

Отзывы: