OPERATION
Safety & Gas Control Information
SAFETY INFORMATION
Contact the factory, the factory representative or a local
service company to perform maintenance and repairs
should the appliance malfunction.
CAUTION
If you smell gas during the lighting procedure,
immediately shut off the gas supply until the
leak has been corrected.
WARNING
In the event of main burner ignition failure, a
5 minute purge period must be observed prior
to re-establishing ignition source.
WARNING
In the event you smell gas, shut down equip-
ment at the main shut off valve and contact
the local gas company or gas supplier for
service.
GAS CONTROL INSTRUCTIONS
The units do not require “lighting” the pilot with a match.
Lighting
NOTE: Unit is shipped with gas combination valve turned
“on”.
1. Open manual gas shut off valve.
2. Set thermostat to OFF, and kettle in fully upright posi-
tion, turn power switch ON.
3. Set thermostat to maximum, initiating a 30 second
pre-purge. Red “COOKING” pilot will come on, and
after 30 seconds, the green “IGNITION” pilot will
come on, lighting the main burners.
If after 36 seconds the burner fails to ignite or the
“ignition light goes out, the system goes into Safety
Lockout. De-energize the system by setting the ther-
mostat to “OFF” for five minutes and try again.
4. Set the thermostat to desired temperature setting.
When temperature setting has been reached, the “IG-
NITION” pilot will go off, turning off the burner. The
unit will then cycle on and off to maintain set tem-
perature.
NOTE: When the kettle is tilted a safety switch will au-
tomatically turn off gas supply. The kettle will not
operate once it has been tilted.
Daily Shutdown
1. Turn power switch “OFF.”
2. Turn thermostat “OFF.”
Complete Shutdown
1. Turn power switch “OFF.”
2. Turn thermostat “OFF”.
3. Turn power supply to unit “OFF”.
4. Remove front access panel on left side and turn dial
on combination valve to “OFF”.
5. Close manual gas shut off valve.