2
INSTALLATION
Service Connections
SERVICE CONNECTIONS
G
Gas Connection
- Supply gas through 3/4” pipe . A gas
shut-off valve must be installed in supply piping convenient
and adjacent to appliance.
EC Electrical Connection
- Unless other wise specified,
Field Wire Electrical Connection to be 120 Volts, 60 Hertz
single phase with grounding wire. Unit furnished with 8’
cord and 3 prong plug. Total max. amps 4.0.
HW Hot Water Connection
- 3/8” tubing to faucet (OP-
TIONAL)
CW Hot Water Connection
- 3/8” tubing to faucet (OP-
TIONAL)
INSTALLATION CLEARANCE
Left Side
Right Side
Rear
0” [0mm]
0” [0mm]
4” [102mm]
BTU/Hour: 125,000
kW/Hour: 36.63
Gas Supply (Supply Pipe Pressure W.C.)
Natural 6”-14” (152-356mm)
Propane 11”-14” (279-356mm)
* Use on non-combustible floors only.
* Shown with option faucet, cover and draw-off.
Ø7/16" [11mm] HOLES
2 EQUALLY SPACED
ON 2.5" [63mm] B.C.
REAR FLANGED FOOT DETAIL
6.38
[162]
36 [914]
WATER LEVEL
PRESSURE
COOK TEMP.
LOW WATER
COOKING
POWER
ON
VEN
T A
IR
20
100
psi
kPa
80
40
TUBE AND CONNECTION
200
0
100
316 SS
300
400
600
500
60
1
OFF
2
3
4
5
6
7
8
9
10
G
38.5
[978]
17.25 [438]
18.75
[476]
2 [51]
3.63 [92]
EC
G
C
H
14.75
[375]
51 [1295]
52.25
[1327]
22.5 [572]
A
33.5 [891]
8.5 [216]
4 [102]
MINIMUM
EC
C
H
G
74.5
[1892]
37.75
[959]
21
[533]
DIMENSIONS ARE IN INCHES [MM]
Figure 1