background image

5

INSTALLATION

Service Connections

Figure 3 

STATIONARY PEDESTAL BASE KETTLES

DIMENSIONS

MODEL

A

B

C

D*

E

F (2”)

F(3”)

G(2”)

G(3”)

H

J

K

L

KPS-20E

21 [533]

18 [457]

38 [965]

25.25 

[641]

18.5 

[470]

14.75 

[375]

15.5 

[394]

18 [457]

17.13 

[435

13.38 

[340]

20.75 

[527]

60.5 

[1537]

16.63 

[422]

KPS-25E

21 [533]

20.5 

[523]

36.75 

[933]

25.25 

[641]

18.5 

[470]

14.75 

[375]

15.5 

[394]

18 [457]

17.13 

[435]

9.5 [241]

17 [432]

58 [1473]

16.5 

[419]

KPS-30E

24 [610]

20 [508]

38 [965]

28.25 

[718]

20 [508]

16 [406]

16.5 

[419]

15.75 

[400]

15 [387]

11.25 

[286]

18.88 

[479]

63.5 

[1613]

16.63 

[422]

KPS-40E

26 [660]

22.5 

[572]

38 [965]

30.25 

[768]

21 [533]

17 [432]

18 [457]

13.5 

[343]

12.5 

[318]

8.88 

[225]

16.38 

[416]

65 [1651]

16.63 

[422]

KPS-60E

29.5 

[749]

26 [660]

42 [1067]

33.75 

[857]

20.63 

[524]

18 [457]

19.25 

[489]

13.88 

[352]

12.88 

[327]

9.63 

[244]

17.13 

[435]

75 [1905]

16.63 

[422]

KPS-80E

33 [838]

28 [711]

45 [1143]

37 [940]

22.38 

[568]

19.5 

[495]

20.5 

[521]

14.88 

[378]

13.88 

[352]

11.25 

[286]

18.63 

[473]

81 [2058]

19.63 

[498]

KPS-100E

35.5 

[902]

30 [762]

48 [1219] 40 [1016]

23.63 

[600]

21.5 

[546]

22.5 

[572]

15 [381]

14.5 

[368]

13 [330]

20.5 

[521]

87 [2210]

19.63 

[498]

* Optional

Safety

Relief Valve

Wall

E

F

NOTE:

2” Valve

Closed 5.13 [130]

Open 6.88 [175]

3” Valve

Closed 7.88 [200]

Open 10.13 [257]

See Note

Air Vent

EC

D

DIMENSIONS ARE IN INCHES [MM]

Optional Faucet Allow

Dimension “D”

Additional 6 [152]

H

J

EC

CW HW

Pedestal

Detail

45°

Front

4 Holes

Ø7/16 [11MM]

Equally  Spaced

L

A

K

C

B

G

KW

PHASE

AMPS PER LINE

208V

220V

240V

380V

415V

480V

12

1

57.7

54.4

50.0

N/A

N/A

N/A

3

33.3

31.5

28.9

18.2

16.7

14.4

15

1

72.1

68.2

62.5

N/A

N/A

N/A

3

41.6

39.4

36.1

22.8

20.9

18.0

18

1

86.5

81.8

75

N/A

N/A

N/A

3

50

47.2

43.3

27.3

25

21.7

24

3

66.6

63.0

57.7

36.5

33.4

28.9

33

3

91.6

86.6

79.4

50.1

45.9

39.7

ELECTRICAL CHARACTERISTICS

AVAILABLE kWn/a

Model

Std Option

Model

Std Option

KLS-20E & 

KLS-25E

12

n/a

KLS-40E

24 15 & 18*

KLS-30E

15

18

KLS-60E, KLS-80E 

& KLS-100E

24

33

* No additional charge for lower kW

SERVICE CONNECTIONS

EC

Electrical Connection to be as specified on data plate.

HW & CW

Hot & Cold Water - 5/8” O.D. Tubing (Optional)

MAXIMUM PRESSURE

All models  50 PSI (345 kPa)

Содержание KLS-100E

Страница 1: ...864 0183 www blodgett PN S00050 Rev F 3 18 2018 G S Blodgett Corporation STATIONARY PEDESTAL MODELS KPS 20E KPS 25E KPS 30E KPS 40E KPS 60E KPS 80E KPS 100E STATIONARY TRI LEG MODELS KLS 20E KLS 25E K...

Страница 2: ...Your Service Agency s Address Model Serial number Kettle installed by Installation checked by...

Страница 3: ...alling or servicing this equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liq uids in the vicinity of this or any other appliance The information contained in this m...

Страница 4: ...ption by the low water cut off device An activated cut off is evidenced by the Low Water light turning on and heating element cut off b Kettle is in vertical position with circuit complet ed through t...

Страница 5: ...Optional View A Flange Foot Detail 4 equally spaced 7 16 holes on a 3 B C D M 70 REF Spring Assist Hinge Cover Optional Extra B C E E See View A L NOTE 60 80 100 gal Kettles are supplied with 2 rear...

Страница 6: ...610 20 508 38 965 28 25 718 20 508 16 406 16 5 419 15 75 400 15 381 11 25 286 18 88 479 63 5 1613 18 457 KLS 40E 26 660 22 5 572 38 965 30 25 768 21 533 17 432 18 457 13 5 343 12 5 318 8 88 225 16 38...

Страница 7: ...30 762 48 1219 40 1016 23 63 600 21 5 546 22 5 572 15 381 14 5 368 13 330 20 5 521 87 2210 19 63 498 Optional Safety Relief Valve Wall E F NOTE 2 Valve Closed 5 13 130 Open 6 88 175 3 Valve Closed 7 8...

Страница 8: ..._E models level by mak ing necessary adjustments on flanged feet 5 Bolt down kettle and seal with Silastic or other equiv alent sealing compound Sealant must be applied not only to bolt heads but also...

Страница 9: ...Rinse inside of kettle thoroughly Drain kettle by tilt ing or if equipped wit h drain valve open valve and remove all food particles Close drain valve 3 Using nylon brush clean kettle with a mild dete...

Отзывы: