Installation
5
Owner’s Responsibilities
1. Oven(s) are uncrated, stacked (if applies) and
put in place.
2. The owner/operator must have the following
utility requirements met and installed.
NOTE: Refer to the Utility Connection infor-
mation provided.
MAXIMUM SHELF LOADING
COS-20G
45,5 Kg (100 lbs)
ELECTRICAL
15 amp grounded outlet
PLUMBING
Water
Water pressure
345 kPa to unit
Cold water supply
19 mm hose fitting
Hot water supply
19 mm hose fitting
Drainage
Atmospheric vented drain
Drain connection
5 cm copper
Average water drain temperature
Approximately 50
_
C
GAS PRESSURE
Gas Connection
BSP/ISO 3/4-14 7/1
Orifice at Sea Level
Steam (gas type --- G20)
5.156 mm diameter
Hot Air (gas type --- G20)
2.00 mm diameter
Inlet Pressure to the Unit
Gas type --- G20
20 mbar
Hot Air Pressure
Gas type --- G20
7.6 mbar
Steam Pressure
Gas type --- G20
8.6 mbar
CALORIFIC INPUT (Nett)
Steam
29.0 KW
Hot Air
49.8 KW
Содержание COMBI COS-20G