18
8.0 TROUBLESHOOTING
1) BURNERS DO NOT COME ON:
a) Gas supply to unit is “OFF”.
b) Manual shut off valve is “OFF”.
c) Thermostat is not turned “ON”.
d) Pan not in lowest position.
e) Ignition Module not functioning.
2) BURNERS PRODUCE CARBON DEPOSITS:
a) Wrong size orifices.
b) Burner air not adjusted properly.
c) Wrong gas supply.
d) Incorrect pressure at supply.
3) BRAISING PAN WILL NOT OPERATE (UP OR DOWN):
a) Motor power supply not “ON”.
b) Defective UP/DOWN switch.
c) SEE TROUBLESHOOTING - HYDRAULICS.
TROUBLESHOOTING - HYDRAULICS:
1) DIRTY OIL:
a) Components not properly cleaned after servicing.
b) Inadequate screening in fill pipe.
c) Air breather left off.
d) Filter dirty or ruptured.
2) FOAMING OIL:
a) Return of tank line not below fluid level.
b) Fluid contamination.
c) Suction leak to pump.