4.3 Electrical Connection 

 

Check that the supply conforms with the requirements listed on the 
factory label and that it is provided with a circuit breaker with sufficient 
earth connection.  Should there be none present, ensure one is supplied 
and installed by a suitably qualified engineer by means of an omnipolar 
switch as indicated in the safety regulations with a minimum clearance of 
the contacts of 

3mm

 
Where the cabinet has to be stored at distance from the power supply, 
ensure that the ensuing connection conforms to all local safety 
regulations.  Cabinets supplied with integral condensing units are supplied 
with an appropriate plug fitted with Neutral and Earth. 
 
The supply cable must be well stretched to avoid coiling and 
superimposition and it must not be exposed to the possibility of damage 
by third parties.  It should be kept clear of liquids, water or heat sources 
and in the event of damage, must be replaced by a suitably qualified 
person.   
 
 
 

4.4 Connection to Drains 

 
The evaporation of the defrost water is automatic in all models with an 
integral condensing unit.  Models with a remote condensing unit can be 
supplied with a heater. 

 
 
 
 

Содержание HB1SS

Страница 1: ...UPRIGHT REFRIGERATOR MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION...

Страница 2: ...Vibration 5 3 Possible Applications 6 Usage 6 1 1 Switching On Off 6 1 2 Temperature Readout 6 1 3 Setting Temperature 6 1 4 Alarm Codes 6 2 Storage of Foodstuffs 6 3 Defrosting 6 3 1 Defrost Timer 6...

Страница 3: ...long and productive life from your machine 2 Manufacturers Retained Rights and Responsibilities It is forbidden reproduce in whole or in part any of these instructions without the express permission o...

Страница 4: ...ment is wrapped in absorbent material and contained and fixed within a fixed pallet and stiff cardboard crate Weights are listed as follows MODEL NET Wt Kg Packing Wt Kg HB1SS 134 148 HB2SS 198 213 LB...

Страница 5: ...efore switching on The equipment must be installed in a suitable environment and not exposed to open air or exposed to rain The correct position to site the unit is away from direct heat sources radia...

Страница 6: ...pply ensure that the ensuing connection conforms to all local safety regulations Cabinets supplied with integral condensing units are supplied with an appropriate plug fitted with Neutral and Earth Th...

Страница 7: ...Suitable Usage Do not use this equipment to maintain and store medical supplies The equipment will operate in unfavourable conditions as registered in Class 4 of the ISO 1992 regulations Amb Temp 30...

Страница 8: ...splayed on the controller as soon as the unit is switched on 6 1 3 Setting The Cabinet temperature By pressing the SET button for 1 second it is possible to read the set temperature To change the temp...

Страница 9: ...alarm Outputs unchanged LA Minimum temperature alarm Outputs unchanged EA External alarm Outputs unchanged CA Serious external alarm All outputs OFF dA Door open Compressor and fan restarts Action On...

Страница 10: ...w moments before reopening Whilst stocking only open and fill one door drawer at a time to eliminate the risk of over balancing 6 3 Defrosting 6 3 1 Defrost Timer The electronic control panel automati...

Страница 11: ...a week Before beginning ensure the unit is disconnected from the power supply then proceed as follows Unscrew and remove protective grill Remove the dust deposited on the front surface of the condense...

Страница 12: ...ed on The controller has been correctly set The cabinet is not defrosting frosting The evaporator is not covered with frost The condenser is not blocked with dust The cabinet is not located close to a...

Страница 13: ...ed with the cabinet The engineer must ensure that there is no possibility of water ingress or damp For replacement or extra parts please scan the QR code below with your smartphone or reader Alternati...

Отзывы: