Custom Static Colors:

1. Use the 

<FUNCTION/TIMER>

 buttons to navigate to 

Red Level

Green Level

, or 

Blue Level

.

2. Then use the 

<UP/DOWN>

 buttons to adjust the intensity level from 

0-255

 (0% 

<--> 100%).
3. Changes are saved automatically upon value change.

Strobe Settings:

1. Use the 

<FUNCTION/TIMER>

 buttons to navigate to 

Strobe Level

.

2. Then use the 

<UP/DOWN>

 buttons to highlight 

Off

, or adjust the value from 

1-255

 (slow to fast).

3. Changes are saved automatically upon value change.

Save and Load Settings:

You can save and load up to 3 customized manual settings. These are the only settings in 
the menu that are required to be manually saved. 

1. Press the 

<MANUAL>

 button to reach the 

Manual Menu

.

2. Use the 

<FUNCTION/TIMER>

 buttons to navigate to 

Save 

or 

Load Settings.

3. Then use the 

<UP/DOWN>

 to select any slot ranging from 

Slot 1-3

.

4. P

ress & hold the 

<UP>

 button for 3 seconds to either save or load from slots 1-3.

Remote Control

 (for use in manual mode only)

1. Plug the wireless receiver into the input on the rear of the machine. 

2. Setup the remote actions for the customizable buttons 4-6.

3. You can use the wireless remote control from up to 25-meters in distance.

Remote Actions (Buttons 4-6)

1. Use 

<FUNCTION/TIMER>

 buttons to navigate to 

Remote Action 4, 5, or 6.

2. Then use 

<UP/DOWN>

 to select any available action 

(see page 9)

.

3. Changes are saved automatically upon selection.

4. Press the 

<FUNCTION> + <TIMER> 

buttons to return home.

Wireless Receiver:

Remote control with 3 customizable 

buttons (numbers 4-6):

•  Button 1: Start Timer

•  Button 2: Stop Timer

•  Button 3: Burst

•  Button 4: As set in menu

•  Button 5: As set in menu

•  Button 6: As set in menu

Содержание atmosFEAR 221b

Страница 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2019...

Страница 2: ...o please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed...

Страница 3: ...20in 50cm from adjacent surfaces Be sure that no air intake slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and...

Страница 4: ...lot configuration to save load settings 5 0L capacity fog fluid tank 3 5 pin XLR signal input outputs Control Protocol USITT DMX 512 DMX channels 11 3 1 channel Removable LCD 6 button control panel wi...

Страница 5: ...it Breaker AC Power Input 3 Pin DMX In Out 5 Pin DMX In Out Wireless Input Removable 6 button LCD control panel Extends 5 meters with included cable 6x 3W 3 in 1 RGB LEDs 5 0L Fog Fluid Tank Mounting...

Страница 6: ...of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of units on a serial data link is 32 fixtures Data DMX Cabling You should use...

Страница 7: ...xture to ensure best communication Fixture Linking Master Slave Mode 1 Connect the male 3 5 pin connector side of the DMX cable to the output female 3 5 pin connector of the first fixture 2 Connect th...

Страница 8: ...below the display which provide functionality and allow you to navigate through the various options Shown below DMX Menu Home Screen This is the top level of the DMX menu structure which displays the...

Страница 9: ...e used they override R G B static colors Off Macros off Rainbow Color macro 1 Fire Color macro 2 Water Color macro 3 Acid Color macro 4 Ether Color macro 5 Storm Color macro 6 Macro Speed Off 1 255 Ma...

Страница 10: ...DOWN to select highlight either Wimpy low output Mild medium output or Blazin high output 3 Changes are saved automatically upon value change Interval Duration Timer Settings Interval settings control...

Страница 11: ...l Menu 2 Use the FUNCTION TIMER buttons to navigate to Save or Load Settings 3 Then use the UP DOWN to select any slot ranging from Slot 1 3 4 Press hold the UP button for 3 seconds to either save or...

Страница 12: ...0 081 100 101 120 121 140 141 160 161 180 181 200 201 220 221 240 241 255 Fog Output Presets No Output Macro 3s Duration 13s Interval Macro 3s Duration 21s Interval Macro 3s Duration 34s Interval Macr...

Страница 13: ...pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the f...

Страница 14: ...ive unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture...

Страница 15: ...Cord A power cord with a minimum of at least 14 AWG must be always used with this machine Light Source LED 6 x 3W RGB 3 in 1 LEDs Optical LED Beam Angle 25 Beam Angle Thermal Max Operating Temp 104 de...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: