5. APPENDIX

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre 

Technology (USITT) as a standardized method for connecting lighting consoles to lighting 

dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility.  The 

Entertainment Services and Technology Association (ESTA) has since assumed control over 

the DMX512 standard.  It has also been approved and recognized for ANSI standard clas-

sification.  

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common 

communications standard used by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each of these channels was origi-

nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting 

console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an 

8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb 

being completely off while 255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan-

dard over two wires. As with microphone cables, a grounded cable shield is used to prevent 

interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two wires for 

“Primary” communication which goes from a DMX source to a DMX receiver, and two wires 

for a “Secondary” communication which goes from a DMX receiver back to a DMX source. 

Generally, the “Secondary” channel is not used so data flows only from sources to receiv-

ers.  Hence, most of us are most familiar with DMX-512 as being employer over typical 

3-pin “mic cables,” although this does not conform to the defined standard.

DMX is connected using a daisy-chain configuration where the source connects to the input 

of the first device, the output of the first device connects to the input of the next device, 

and so on. The standard allows for up to 32 devices on a single DMX link.

Troubleshooting

Symptom

Solution

Fixture Auto-Shut 

Off

Check the fan in the fixture. If it is stopped or moving slower than 

normal, the unit may have shut itself off due to high heat. This is to 

protect the fixture from overheating. Clear the fan of obstructions, 

or return the unit for service.

No Light Output

Check to ensure fixture is operating under correct mode.

No Power

Check fuse, AC cord and circuit for malfunction.

Blown Fuse

Check AC cord and circuit for damage, verify that moving parts are 

not restricted and that unit’s ventilation is not obstructed

Fixture Not 

Responding / 

Responding Er-

ratically

Make sure all connectors are seated properly and securely.

Use Only DMX Cables and/or check cables for defects

Install a Terminator.

Reset fixture(s).

Содержание OBERON PROFILE NZ

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2016 Profile NZ WZ...

Страница 2: ...Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Connection With Mains 9 Mounting Rigging 9 Gobo Holder 9 Color Gel Frame 9 4 Operat...

Страница 3: ...re you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average...

Страница 4: ...fore servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT oper...

Страница 5: ...r 15 28 zoom Profile NZ or 20 45 zoom Profile WZ Low power consumption Standalone master slave mode 3 5 pin DMX input output ADDITIONAL FEATURES USITT DMX 512 1 2 channels 4 button LCD control panel m...

Страница 6: ...T POWER OUTPUT DMX512 ON OFF OUT IN DMX512 FUSE ESC ENTER DOWN UP OUT IN F Power Supply AC100 240V 50 60HZ Power Consumption 200W 1 08A PF 63 WARNINGS Never look directly into light source A good grou...

Страница 7: ...serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximu...

Страница 8: ...use the 5 pin DMX input and or output connec tions found on the back of your fixture s Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Dat...

Страница 9: ...amp The clamp should be rated to hold at least 10x the fixture s weight to ensure structural stability Do not mount to surfaces with unknown strength and ensure properly rated rigging is used when mou...

Страница 10: ...e the current selection DOWN Scrolls through menu items and numbers in descending order UP Scrolls through menu items and numbers in ascending order The control panel LCD display shows the menu items...

Страница 11: ...OFF and press the ENTER button to confirm your choice Perform Function Demo Allows users to set the fixture perform beam and strobe demos 1 Navigate the main menu to reach Perform Function and press...

Страница 12: ...ith other signals There are five pins on a DMX connector a wire for ground cable shield two wires for Primary communication which goes from a DMX source to a DMX receiver and two wires for a Secondary...

Страница 13: ...a unit in for service But like any com plex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving lik...

Страница 14: ...l Beam Angle 15 28 degree zoom Profile NZ 20 45 degree zoom Profile WZ Luminous Flux 17 000lm 18 000lm CRI 95Ra Gobo Size 85mm image size 60mm Thermal Max Operating Temp 104 degrees F 40 degrees C amb...

Страница 15: ...Page 15 Oberon Profile NZ WZ Rev A 2016 Blizzard Lighting LLC PROFILE NZ 15 PROFILE WZ 20 PROFILE WZ 45 PROFILE NZ 28 Photometric Data Oberon Profile NZ Oberon Profile WZ...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: