Blitz SBC i-D Скачать руководство пользователя страница 6

BOOST

1

In order to set desired boost

MANUAL

 - Setting the boost pressure manually.

Press MENU button, scroll down to BOOST and

WARNING

 - the number displayed does not represent actual boost.

press enter.  

It is a ratio,  0 represents stock boost,  100 represents maximum

2

To select function, scroll down and press enter 

boost.

The function will be highlighted, scroll to select or set 

*

Always start off with a low amount ratio, then adjust to preference

different setting.

IMPORTANT 

- Boost and EGT gauges must be used when setting the

3

To unselect, press MENU button to go to previous display.

SBC I-D.  Always start with the boost ratio set at low then slowly 
adjust to desired setting.

Note:

 Each channel can be set differently, either to AUTO or MANUAL

BOOST

SET

CHANNEL           

CH1

- Shows the boost ratio or boost pressure setting

AUTO / MANU     AUTO

1

To change boost setting press enter and scroll down to SET

SET                    

0.6

and press enter and scroll left or right to adjust setting.

GAIN                       

5

2

While in 

Boost Digital Display

, the Channel and Boost setting can

GRAPH SCALE      

1.0

be change without going to Boost setting.  Channel and Boost 
setting is located under boost digital bar.  By pressing enter
Channel will be highlighted, scroll to Channel desired.  Press enter
again to go to boost setting, set as desired.

EXPLANATION OF EACH CATEGORY

GAIN

CHANNEL

- Ratio of 0-100

 

Channel 1 ~ Channel 4

- Gain controls the boost response.  The high the gain setting,

 

SBC I-D has 4 programmable boost settings.  Each channel has its

the faster the boost response will be.  Stock turbo charged 

own individual memory and will not affect any other channels.  

vehicles with actuator type wastegates will usually use a gain 

 

EXT 

setting of 5-15 percent.  External type wastegates usually

Only use with the Blitz MAP Analyzer, refer to Map Analyzer

requires higher gain setting.

instructions

WARNING

 - High gain setting might cause boost spikes.

OFF

Note

: Each channel can be set to each individual gain setting

Turns boost controller off, boost pressure will be at stock.

GRAPH SCALE

AUTO / MANUAL

You can select the graph scale that appears on your display

AUTO

 - Full automatic mode

screen.

1.0  ~  1.5  ~  2.0  ~  2.5 kg/cm

2

Dial in desire amount of boost pressure to set boost

example:

1.0  ~  1.5  ~  2.0  ~  2.5 x100kpa

WARNING - Auto mode will not work properly on any twin 

1.0  ~  1.5  ~  2.0  ~  2.5 BAR

turbo, sequential turbo, or high boosting vehicles.

10  ~  20  ~  30  ~  40 PSI

Note

: Each channel can be set to different graph scale

Page 6

Содержание SBC i-D

Страница 1: ...st pressure is close to desired boost setting Switching from wastegate to actuator can be done in controller WARNING This device is to change boost pressure but does not give or reduce fuel to the veh...

Страница 2: ...cles may need a boost and fuel cut device Installation of valve unit Keep the valve unit away from hot components but keep within three feet from the turbo CAUTION more than three feet away from the t...

Страница 3: ...nit Use connector to connect hose from valve unit to turbo compressor Use hose clamp to hold hose and connector together Use hose connector to connect hose from valve unit to actuator Diagram 3 Use ho...

Страница 4: ...main harness to controller coupler Connect the other end of the harness to valve unit Use Teflon hose and connect to pressure port in controller to after the throttle body on the intake manifold Use...

Страница 5: ...To use please refer to Page DATA Optional features Refer to Page 9 MAIN MENU AUTO PEAK Automatic Peak hold reset 2 How to set To set refer to Page 9 REPLAY Press enter to select AC WG Actuator Wasteg...

Страница 6: ...s located under boost digital bar By pressing enter Channel will be highlighted scroll to Channel desired Press enter again to go to boost setting set as desired EXPLANATION OF EACH CATEGORY GAIN CHAN...

Страница 7: ...The LCD backlight will turn red if boost exceeds warning setting Scramble boost is operated by throttle response scramble will automatically BUZZER Allows the user to choose to turn buzzer off the uni...

Страница 8: ...n digital display SBC I D Unit setting to PSI GRAPH DATA 1 DATA 1 in graph display Explanation of Speed Map Diagram DATA 2 DIGITAL DATA 2 DATA 2 in digital display The Diagram above shows that the veh...

Страница 9: ...FIT 0 00 HIGH V 12 0 HIGH V 16 0 CONTRAST FIT 200 FIT 16 0 To set press MENU and go to Main Menu Scroll to CONTRAST UNIT C UNIT VOLT and press enter Scroll to adjust press enter to set DATA BRIGHT To...

Страница 10: ...play Display description NOW Actual boost pressure PEAK Peak boost pressure To reset Peak Press REC STOP and MENU at the same time REC Record WR Warning SC Scramble Boost Shortcuts Hold Enter for 3 se...

Страница 11: ...ower Meter I D OPTN 1 will only work if Power Meter I D is connected OPTN 1 will only work if Power Meter I D is connected When Power Meter I D is connected OPTN 1 will When Power Meter I D is connect...