Blitz SBC i-D Скачать руководство пользователя страница 2

SBC-ID Installation 

Use caution on Installation

* Be aware to make sure that the installation on valve unit is correct

on in and out ports.

* Check for pressure leaks in hoses.
* Cut hoses straight down and not in an angle.
* Check and make sure that hoses are clamped tight for no leakage.
* Keep the rubber hoses away from heat sources such as the

exhaust manifold and etc.

* Keep the valve unit and hoses away from moving parts.
* Some vehicles may need a boost and fuel cut device.

Installation of valve unit

* Keep the valve unit away from

hot components but keep within
three feet from the turbo.

*

CAUTION

: more than three feet

away from the turbo can cause 
bad response with boost surge
or boost spike.

* Use hose enlargement adapter to 

connect hose to valve unit and use 
hose clamp to prevent leakage.

* Connect main wiring harness to

 valve unit.

* Connect main wiring harness to controller.
* Connect display to controller.

WARNING:

  keep hands away from hot engine components.  Install 

when entire engine bay has cooled.  Turbo may still be hot even after
engine has cooled.

Page 2

Содержание SBC i-D

Страница 1: ...st pressure is close to desired boost setting Switching from wastegate to actuator can be done in controller WARNING This device is to change boost pressure but does not give or reduce fuel to the veh...

Страница 2: ...cles may need a boost and fuel cut device Installation of valve unit Keep the valve unit away from hot components but keep within three feet from the turbo CAUTION more than three feet away from the t...

Страница 3: ...nit Use connector to connect hose from valve unit to turbo compressor Use hose clamp to hold hose and connector together Use hose connector to connect hose from valve unit to actuator Diagram 3 Use ho...

Страница 4: ...main harness to controller coupler Connect the other end of the harness to valve unit Use Teflon hose and connect to pressure port in controller to after the throttle body on the intake manifold Use...

Страница 5: ...To use please refer to Page DATA Optional features Refer to Page 9 MAIN MENU AUTO PEAK Automatic Peak hold reset 2 How to set To set refer to Page 9 REPLAY Press enter to select AC WG Actuator Wasteg...

Страница 6: ...s located under boost digital bar By pressing enter Channel will be highlighted scroll to Channel desired Press enter again to go to boost setting set as desired EXPLANATION OF EACH CATEGORY GAIN CHAN...

Страница 7: ...The LCD backlight will turn red if boost exceeds warning setting Scramble boost is operated by throttle response scramble will automatically BUZZER Allows the user to choose to turn buzzer off the uni...

Страница 8: ...n digital display SBC I D Unit setting to PSI GRAPH DATA 1 DATA 1 in graph display Explanation of Speed Map Diagram DATA 2 DIGITAL DATA 2 DATA 2 in digital display The Diagram above shows that the veh...

Страница 9: ...FIT 0 00 HIGH V 12 0 HIGH V 16 0 CONTRAST FIT 200 FIT 16 0 To set press MENU and go to Main Menu Scroll to CONTRAST UNIT C UNIT VOLT and press enter Scroll to adjust press enter to set DATA BRIGHT To...

Страница 10: ...play Display description NOW Actual boost pressure PEAK Peak boost pressure To reset Peak Press REC STOP and MENU at the same time REC Record WR Warning SC Scramble Boost Shortcuts Hold Enter for 3 se...

Страница 11: ...ower Meter I D OPTN 1 will only work if Power Meter I D is connected OPTN 1 will only work if Power Meter I D is connected When Power Meter I D is connected OPTN 1 will When Power Meter I D is connect...

Страница 12: ...Power Meter I D OPTN 2 will only work if Power Meter I D is connected OPTN 2 will only work if Power Meter I D is connected When Power Meter I D is connected OPTN 2 will When Power Meter I D is connec...

Страница 13: ...electronic outputs from displaying electronic outputs from the ECU such as temperature voltage the ECU such as temperature voltage pressure TPS A F and etc pressure TPS A F and etc Optional harness i...

Страница 14: ...of screen and recording will start To stop recording press Rec Stop again and the REC will disappear To Replay 1 Scroll to Replay in main menu and press Enter Note OPT1N and OPTN 2 will display Speed...