Charge on.
BlinkCharging.com
Page 53 of 56
9.3.1.
Plug and Charge
1.
Insert the charging plug into the EV
2.
Charging session started
9.3.2.
RFID card
1.
Insert the charging plug into the EV
2.
Swipe card
3.
Waiting for authorizing
4.
Charging session started
9.4.
Stop Charging
9.4.1.
Interrupt Charging
1.
Unplug any time (disconnect the charging plug from EV to stop charging session)
2.
Session ended (please return the connector to the holster)
9.4.2.
Auto Restart
When a charging session is interrupted due to a temporary error condition, the EVSE will automatically
restart charging when the cause of the temporary error condition returns to normal. Status indicator lights
remain flashing RED until the error condition is resolved.
•
Temporary error conditions include: Over Current, Over Voltage, Under Voltage, and Over
Temperature.
•
For Over Current conditions: The charging session will be stop while OC occurs. After recovery
from OC for 30 seconds, the EVSE will automatically restart charging for three times.
•
When charging session stopped due to CCID trip, the EVSE will try to restart after 15 minutes for
3 times.
9.4.3.
Cold Load Pickup
When power resumes after an outage, the EVSE restarts automatically with a delay ranging from 120 to
720 seconds. The delay is designed to avoid impacting the utility grid when multiple EVSEs are in the
same area attempting to resume charging simultaneously.