Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 13 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
FOR REFERENCE ONLY
b)
Read LED ON
The LED have the same mapping of Set LED ON message
•
PKP-2400-SI
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
01h
CAN Object 2001h
Byte 2
20h
Byte 3
XXh
XX: Sub index
01h: Red Led
02h: Green Led
03h: Blue Led
Byte 4,7
00h
Not used
Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
40 01 20 01 00 00 00 00
Read red LED
Keypad reply
595
Std
4F 01 20 01 08 00 00 00
Only red LED #4 ON
To Keypad
615
Std
40 01 20 02 00 00 00 00
Read green LED
Keypad reply
595
Std
4F 01 20 02 01 00 00 00
Only green LED #1 ON
To Keypad
615
Std
40 01 20 03 00 00 00 00
Read blue LED
Keypad reply
595
Std
4F 01 20 03 20 00 00 00
Only blue LED #6 ON
16.