Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 19 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
FOR REFERENCE ONLY
To Keypad
615
Std
2F 11 20 00 00 00 00 00
Boot-up service not active
Keypad reply
595
Std
60 11 20 00 00 00 00 00
20.
Object 2012h: Set device active on startup
If keypad is active on startup don’t need the Start CANopen command from host.
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
12h
CAN Object 2012h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used
Example:
Direction
Identifier Format
Message
Data
To Keypad
615
Std
2F 12 20 00 01 00 00 00
Device active on startup
Keypad reply
595
Std
60 12 20 00 00 00 00 00
21.
Object 2013h: Set CANopen node ID
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
13h
CAN Object 2013h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
XX: New node id (00h-7Fh),
default 15h
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 13 20 00 17 00 00 00
New CANopen node ID 17h
Keypad reply
597
Std
60 13 20 00 00 00 00 00
22.
Object 2014h: Set startup LED show
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
14h
CAN Object 2014h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Disable
01h: Complete LED Show (default)
02h: Fast Flash
Byte 5,7
00h
Not used
Example:
Direction
Identifier Format
Message
Data
To Keypad
615
Std
2F 14 20 00 00 00 00 00
Disable startup LED show