Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 32 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
FOR REFERENCE ONLY
Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
40 00 18 00 00 00 00 00
Keypad
reply
595
Std
4F 00 18 00 05 00 00 00
5
To Keypad
615
Std
40 00 18 01 00 00 00 00
Keypad
reply
595
Std
43 00 18 01 95 01 00 00
0000 0195h
To Keypad
615
Std
40 00 18 02 00 00 00 00
Keypad
reply
595
Std
4F 00 18 02 FE 00 00 00
FEh: event-driven type
To Keypad
615
Std
40 00 18 05 00 00 00 00
Keypad
reply
595
Std
4B 00 18 05 00 00 00 00
0000h: Periodic
transmission disabled.
To Keypad
615
Std
2F 00 18 02 01 00 00 00
Set the Synchronous
transmission (cyclic
every SYNC).
Keypad
reply
595
Std
60 00 18 02 00 00 00 00 ACK
To Keypad
80
Std
-
SYNC message
received
Key #1 pressed No message on the CAN bus
From
Keypad
195
Std
00 00 00 00 XX
Key status sent/
Read key status
To Keypad
80
Std
-
SYNC message
received
From
Keypad
195
Std
01 00 00 00 XX
Key status sent/
Read key status
Transmit PDO communication Parm 0:
•
Highest sub-index supported: 5;
•
Address base: 195h= 180h+ NODE ID;
•
Transmission Type: synchronous or event-driven;
•
Periodic Transmission timer: XXYY in milliseconds, 0 = OFF.
b)
Set periodic state transmission
Identifier
600h + current
CAN ID
Default 615h
Byte 0
2Bh
Set device register
Byte 1
00h
CAN Object 1800h
Byte 2
18h
Byte 3
05h
Sub index
Byte 4
YYh
YYh: Periodic transmission timer in milliseconds
LSByte
Byte 5
XXh
XXh: Periodic transmission timer in milliseconds
MSByte
Byte 6, 7
00h
Not used
Periodic Transmission timer: XXYYh (from 000Ah to FEFFh: from 10 to 65279 milliseconds).