Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
2B 00 18 05 00 00
00 00
Switch off the periodic
state transmission
Keypad
reply
595
Std
60 00 18 05 00 00
00 00
Command accepted
To Keypad
615
Std
2B 00 18 05 32 00
00 00
Set period = 50ms
Keypad
reply
595
Std
60 00 18 05 00 00
00 00
Command accepted
To Keypad
615
Std
2B 00 18 05 F4 01
00 00
Set period = 500ms
Keypad
reply
595
Std
60 00 18 05 00 00
00 00
Command accepted
45.
Object 1A00h Transmit PDO Mapping Parameter
Describes the mapping of Key state PDO Message.
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
00h
CAN Object 1A00h
Byte 2
1Ah
Byte 3
00h
Number of mapped objects
01h
PDO Mapping Entry 1
Byte 4,7
00h
Not used
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 00 1A 00 00 00 00 00
Keypad reply
595
Std
4F 00 1A 00 01 00 00 00
1
To Keypad
615
Std
40 00 1A 01 00 00 00 00
Keypad reply
595
Std
43 00 1A 01 08 01 00 20 2000 01 08
Transmit PDO Mapping Parameter:
•
Number of mapped objects: 1;
•
Switch state: Object 2000h, Sub index 01h, Length 08h.