FITTING INSTRUCTIONS 2/3
STEP 3
Safety Device
Cord safety cleat - The safety cleat shall be installed as close to
the headrail as possible and in all cases not less than 1500mm
from the floor.
The Cord must be fully accumulated around the
safety cleat(s) when the blind is not in use. Use the table below
to determine the distance required between the cleats to fully
accumulate the cords when the blind is fully raised.
Place the safety cleat in the desired position on the wall and
mark the positions of the holes with a pencil.(Note: Based on
cord up to 2.8mm, 17mm can be accumulated in total.)
Mark the hole positions and drill as
required.
Swivel Bracket (Optional)
Swivel brackets can be face or top fixed. One Swivel bracket should be
attached adjacent to each ladder without interfering with the internal
components. Open the swivel arm feed the headrail into the bracket as
shown and lock the swivel arm closed.
End Fixing (Optional)
End Fix brackets can be both top and
end fixing. The brackets should be positioned
6mm wider than the blind at each end. Hold
each bracket into place and mark the hole
positions. Fit each bracket using the screws
provided. Please ensure fixings are suitable
for the wall/surface to which you are mounting
the brackets.
Open the gate of the box brackets and slide
the headrail into position then snap the
brackets closed.
Hold Down Bracket
(Optional)
Hold down brackets:Using two small screws,
screw hold down bracket to window facing or
wall. Snap bracket pin ends into the hole at
bottom rail end.
Page 3 of 6
(Hold down bracket)
(End Fixing 1/2)
(End Fixing 2/2)