DANGER: 

ALWAYS remove the lid hatch on top of the keg BEFORE removing 

the v-band clamp on the bottom of the keg!  This ensures that the keg is fully 

depressurized.

DANGER

: NEVER exceed the 50 PSI (3.3 BAR) rated pressure!

DANGER

: Only use the pressure relief valve that is included with this product.  

Do not modify or tamper with the relief valve.  Using the incorrect parts or  

tampering with the pressure relief valve can lead to serious injury or death!

DANGER:

 DO NOT use any pressure relief valve components or the 

lid hatch on any keg other than the Cornical™ or serious injury or 

death could result!

DANGER:

 ALWAYS use a blowoff hose or airlock during fermentation.  

Do NOT use the solid lid or cap the NPT fitting on the fermentation lid 

while the beer is actively fermenting.

Cleaning & Sanitizing the Keg:

DANGER – DEPRESSURIZE KEG BEFORE OPENING OR REMOVING CLAMP: 

 Before opening or removing the 

v-band clamp ALWAYS first relieve ALL internal pressure from the keg by pulling the ring on top of the pressure relief 

valve until all hissing stops (Fig. 4.)  Then remove the lid hatch on top of the keg (Fig. 5.)  Continue to fully  

disassemble the keg including the removal of the keg posts and pressure relief valve (PRV).  It is not necessary to 

disassemble the posts or PRV further.

Soak all parts in a suitable cleaning agent such as PBW (powdered brewery wash) or similar cleaner.  Scour the inside 

of the keg body and the keg bottom.  It is important that ALL parts are free of soil for the sanitizer to work properly.  

Rinse all components in hot water and allow to dry thoroughly so that the passive layer forms on the  

surface of the stainless steel.

Prepare a 3-4 gal bucket of sanitizer.  We recommend StarSan from Five Star products.  However, any  

non-chlorine based no-rinse sanitizer including Iodophor are acceptable.  Soak all fittings in the sanitizer before 

assembly.  Recommended, but not included, is a long brush for cleaning the inside of the liquid out tube.  These are 

available at your retailer. 

CAUTION: 

Iodophor CAN be harmful to stainless steel if exposed for long periods of time.  Never store a keg with 

Iodophor inside.  Do not use any cleaner or sanitizer containing chlorine such as bleach.  Over time, this will pit and 

erode stainless steel.  This is not a warrantable failure.

CAUTION:

 Do not soak the V-band clamp or brass nut in sanitizer.  Doing so reduces the life of the threads and may 

cause galling (sticking) of the threads.  Clean only with warm soapy water if needed.  Always place a dab of Vaseline or 

keg lube on the threads of the v-band clamp each time before assembly.  This helps to increase the life of the threads 

and makes assembly easier.  Galled, cross-threaded, or other thread damage from failure to use lube or soaking in 

sanitizer is not a warrantable failure.

Fig 6

Fig 5

Содержание Cornical

Страница 1: ...mann Engineering www BlichmannEngineering com before use Sections labeled Caution can lead to equipment damage or unsatisfactory performance of the equipment Please read these sections thoroughly If you have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Danger are critical to follow and understand to reduce risk of serious inj...

Страница 2: ...it 10 Racking O Ring 7 Aseptic Valve 19 QuickConnector cap 18 QuickConnector nut 20 QuickConnector elbow 14 Elbow 1 5 5 Tri Clamp Butterfly 1 5 11 Clamp 1 5 12 Gasket 1 5 13 Cap 1 5 24 Fermentation Lid Hatch Dump Assembly Dump Assembly Racking Assembly 6 QuickConnect 1 2 Straight 8 Racking Tube 9 Racking Tube Nut Fig 3 Assembly of the Keg Kit Note We recommend a trial assembly of your new Cornical...

Страница 3: ... to disassemble the posts or PRV further Soak all parts in a suitable cleaning agent such as PBW powdered brewery wash or similar cleaner Scour the inside of the keg body and the keg bottom It is important that ALL parts are free of soil for the sanitizer to work properly Rinse all components in hot water and allow to dry thoroughly so that the passive layer forms on the surface of the stainless s...

Страница 4: ...e the keg in an inverted position to let the sanitizer drain fully Then return the keg upright and replace the lid hatch Connect a black LIQUID ball lock on your CO2 hose Connect it to the liquid out post This purges the keg from the bottom up Pull the pressure relief valve and turn it 90 degrees so that it stays in the open position Turn on your CO2 gas and let the gas run for about 30 seconds to...

Страница 5: ... water and then soak in a bucket of 4 5 gal of sanitizing solution Assemble the bottom dump components sanitary elbow gaskets butterfly valve 1 5 cap and clamps as shown in Fig 3 Assemble the racking arm components small elbow nut fittings o ring gasket and sampling valve as shown in Fig 3 For the racking arm ensure that the o ring is in the groove of the racking fitting Then use a wrench on the i...

Страница 6: ...ential for proper yeast health An inline oxygenation system is available through Blichmann Engineering ANVIL Brewing Equipment also offers a high quality oxygenation wand Harvesting yeast If you re harvesting the yeast for use in a future batch of beer you ll need to sanitize the included 1 hose and the 1 hose barb fitting first The inside of the valve can easily be sanitized by a spray bottle of ...

Страница 7: ...uid runs from the hose Remove the barb and hose spray the inside of the valve with sanitizer and reinstall the cap Wait a couple days for more yeast to settle and repeat TIP If the yeast has compacted and will not flow from the valve close the valve Install the cap on the lid hatch and pressurize the fermentor to about 5 10 PSI with CO2 Then SLOWLY open the valve and the yeast should begin to flow...

Страница 8: ...ble and sold separately Optional NPT Spunding Valve is perfect for the Blichmann Engineering Cornical Unitank Accessories After ensuring all of the yeast sediment has been expelled from your fermentor you will need to measure the beer level in the fermentor to ensure it is less than 5 gal so that it doesn t spill when you remove the cone bottom To do this connect the sanitized hose to the outlet o...

Страница 9: ... any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited...

Отзывы: