background image

Cornical

™ - V3

 

© Blichmann Engineering, LLC 2020 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

2

What’s In the Box?

1.  Cone

2.  Leg (installed on cone)

3.  Acorn nut (installed on cone)

4.  Leg cap (installed on legs)

5. 

Tri-clamp butterfly valve (1.5 in)

6.  QuickConnect 1/2” Straight

7.  Aseptic Valve

8.  Racking tube

9.  Racking tube nut

10.  Racking o-ring

11.  Clamp – 1.5”

12.  Gasket 1.5”

13.  Cap – 1.5”

14.  Elbow – 1.5”

15. 

Barb fitting – 1.5” TC X 1” hose

16.   

17. 

18.  QuickConnector nut

19.  QuickConnector cap

20.  QuickConnector ½” elbow

21.  QuickConnector o-ring

22.  Hose – ½” blowoff

23.  Hose clamp

23.  Fermentation lid hatch

23.  Airlock

23.  Airlock washer

23.  1” ID bottom dump  

hose

BE-000547-03

BE-000939-01

BE-000028-00

BE-001022-00

BE-000865-00

aQC_12S

FE-367-01

FE-357-00

FE-376-03

BE-000682-00

BE-000633-00

BE-000868-00

BE-000630-00

BE-000863-00

BE-000627-00

QC-12NUT-01

BE-001017-00

QC-12ELBOW-01

BE-000105-00

BE-000707-00

BE-000374-00

BE-000944-01

BE-500019-00

BE-001018-00

BE-001100-00

Conical Fermentor Kit

10.  Racking O-Ring

7.  Aseptic Valve

19.  QuickConnector™ cap

18.  QuickConnector™ nut
20.  QuickConnector™ ½” elbow

14.  Elbow 1.5”

5. 

Tri-Clamp Butterfly 1.5”

11.  Clamp 1.5”

12.  Gasket 1.5”

13.  Cap 1.5”

24.  Fermentation  

        Lid Hatch

Dump

Assembly

Dump

Assembly

Racking 

Assembly

6. QuickConnect™ 1/2” Straight

8.  Racking Tube

9.  Racking Tube Nut

Fig 3

Assembly of the Keg Kit: 

Note: We recommend a trial assembly of your new Cornical™ keg before using it to ferment so you are familiar with the 

procedures and are sure you have all the parts.  When you are ready to use the fermentor for an actual brewing session, 

read the sanitizing procedures before assembling your Cornical™ since many parts are sanitized before assembly.  

DANGER: 

ALWAYS release the pressure inside of the keg before 

attempting to open the keg or loosening the nut on the v-band clamp!  If 

this clamp is opened while under pressure serious injury or death may 

result!  Relieve pressure by pulling the ring on the top of the pressure 

relief valve until the hiss of gas completely stops (Fig 4.)  Remove the 

hatch on top of the keg to ensure all pressure is released (Fig. 5)!  At this 

time it is safe to remove the v-band clamp from the bottom of the keg 

(Fig. 6.) 

Fig 4

Содержание Cornical

Страница 1: ...mann Engineering www BlichmannEngineering com before use Sections labeled Caution can lead to equipment damage or unsatisfactory performance of the equipment Please read these sections thoroughly If you have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Danger are critical to follow and understand to reduce risk of serious inj...

Страница 2: ...it 10 Racking O Ring 7 Aseptic Valve 19 QuickConnector cap 18 QuickConnector nut 20 QuickConnector elbow 14 Elbow 1 5 5 Tri Clamp Butterfly 1 5 11 Clamp 1 5 12 Gasket 1 5 13 Cap 1 5 24 Fermentation Lid Hatch Dump Assembly Dump Assembly Racking Assembly 6 QuickConnect 1 2 Straight 8 Racking Tube 9 Racking Tube Nut Fig 3 Assembly of the Keg Kit Note We recommend a trial assembly of your new Cornical...

Страница 3: ... to disassemble the posts or PRV further Soak all parts in a suitable cleaning agent such as PBW powdered brewery wash or similar cleaner Scour the inside of the keg body and the keg bottom It is important that ALL parts are free of soil for the sanitizer to work properly Rinse all components in hot water and allow to dry thoroughly so that the passive layer forms on the surface of the stainless s...

Страница 4: ...e the keg in an inverted position to let the sanitizer drain fully Then return the keg upright and replace the lid hatch Connect a black LIQUID ball lock on your CO2 hose Connect it to the liquid out post This purges the keg from the bottom up Pull the pressure relief valve and turn it 90 degrees so that it stays in the open position Turn on your CO2 gas and let the gas run for about 30 seconds to...

Страница 5: ... water and then soak in a bucket of 4 5 gal of sanitizing solution Assemble the bottom dump components sanitary elbow gaskets butterfly valve 1 5 cap and clamps as shown in Fig 3 Assemble the racking arm components small elbow nut fittings o ring gasket and sampling valve as shown in Fig 3 For the racking arm ensure that the o ring is in the groove of the racking fitting Then use a wrench on the i...

Страница 6: ...ential for proper yeast health An inline oxygenation system is available through Blichmann Engineering ANVIL Brewing Equipment also offers a high quality oxygenation wand Harvesting yeast If you re harvesting the yeast for use in a future batch of beer you ll need to sanitize the included 1 hose and the 1 hose barb fitting first The inside of the valve can easily be sanitized by a spray bottle of ...

Страница 7: ...uid runs from the hose Remove the barb and hose spray the inside of the valve with sanitizer and reinstall the cap Wait a couple days for more yeast to settle and repeat TIP If the yeast has compacted and will not flow from the valve close the valve Install the cap on the lid hatch and pressurize the fermentor to about 5 10 PSI with CO2 Then SLOWLY open the valve and the yeast should begin to flow...

Страница 8: ...ble and sold separately Optional NPT Spunding Valve is perfect for the Blichmann Engineering Cornical Unitank Accessories After ensuring all of the yeast sediment has been expelled from your fermentor you will need to measure the beer level in the fermentor to ensure it is less than 5 gal so that it doesn t spill when you remove the cone bottom To do this connect the sanitized hose to the outlet o...

Страница 9: ... any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited...

Отзывы: