temp
sensor
pro
MINIATURE TEMPERATURE SENSOR WITH EXTERNAL ANTENNA
Improper connections may be dangerous, it can damage
the controller, and loss of the warranty.
Disconnect supply voltage circuit before installing the controller.
Remember that any mounting works should be carried out when
the main voltage is disconnected (switch off the mains fuse or
disconnect the power supply from the socket).
The controller should be installed in a place protected against
accidential destroyment. The measurement probe is waterproof. It
is not allowed to install the probe in a place exposed to contact
with oils, liquid fuels, solvents and caustic substances, as well as in
places exposed to the direct action of high temperatures. Remem-
ber that metallic elements (wires, large fitting elements) have a
negative influence on the range of the device, and consequently
the comfort of use. It is recommended that the device be mounted
in a stable and fixed position with the antenna upside. When
installing the device outside of dry rooms, pay special attention to
provide tightness of the rubber cable glands.
Read the diagram and then proceed to install the controller. Pay
particular attention to the designation of the controller connec-
tors. Start by connecting (from left) the GND (black) and
+12V/+24V power wires (red or black with a white dotted line).
A digital probe was used to measure the temperature. It is not
recommended to extend the original temperature probe cable
excessively since the induced interference can cause the controller
malfunction or even damage it.
Than connect the external temperature probe, in the order of wire
colors (from left): black, red and yellow or white, brown and green.
If the additional probes ares also installed they must be connected
in parallel. The last connector, on the far right, must be left uncon-
nected, it has been designed to allow the expansion of the
capabilities of the product and is currently not used.
After making sure that the device is connected in accordance with
the diagram and that there are no metal components near the
controller which may accidentally cause short-circuit, start the
device by turning on the power (turning on the mains fuse or
connecting the power cord to the power outlet).
DANGER! Risk of electric shock! Even with the device
turned off, the outputs may be live. All assembly work
should be ALWAYS performed with the disconnected
power circuit.
The installation of the device to a power mains that does
not meet the quality requirements defined by EN 50081-1,
EN 50082-1, UL508, EN 60950, will result in the loss of the
warranty.
SAFETY RULES
INSTALLATION - BASICS
temperature sensor with
the μWiFi technology
CONNECTION DIAGRAM
max 4 sensors
User manual
+
-