DISCLAIMER

 

 
The supplier or manufacturer shall not be liable for any damage. This directly relates to heath, life, property or 
any  monetary  loss  caused,  due  to  failure  to  comply  with  instructions  for  installation,  use,  assembly, 
maintenance, functional testing, safety, or any other instructions provided in this user manual. 

 

SYSTEM OPERATION 

 
Designed to protect small enclosed spaces with risks of fire. Simple and easy to install, the BlazeCut T Series 
system operates automatically without any external power source. The extinguishing agent is stored in a tube, 
which also applies the extinguishing agent directly to the fire at its source. When a fire occurs, the combination 
of heat and internal pressure causes the tube to rupture, creating a nozzle, releasing the extinguishing agent. 
 

WARNINGS AND CAUTIONS

 

 
Please ensure that the safety instructions are fully understood before the equipment is put 
into service. 

Do not modify any part of the BlazeCut components as this  may void warranty, impair the 
performance of this product and cause damage or serious injury.

 

Always wear the appropriate protective equipment and clothing whilst installing or servicing. 

The  BlazeCut  T  Series  is  designed  as  independently  operating  unit.  It  is  not  possible  to 
connect several independent systems into one unit. 

The BlazeCut T Series is not compatible with other fire suppression systems, do not try to 
connect the system to any other equipment. 

The  system  may  be  installed  only  by  adult  persons,  physically  and  mentally  capable. 
Incorrect  interference  with  the system may  cause  malfunction  of  the  system  and  provides 
threat to safety and health of people. 

The system is under constant pressure, any mechanical interference is prohibited. 

Never unscrew the pressure gauge, the sealing screw or the pressure switch mounted on the 
fittings. 

Beware  of  any  manipulation  with  the  system  if  the  system  has  been  subjected  to  higher 
temperatures. When the system is heated (e.g. during the operation of the device), the gas 
pressure in the tube increases. If the pressure in the system is higher than 17 bar (247 psi) 
the  system  is  reaching  burst  pressure.  In  this  case,  the  tube  must  not  be  mechanically 
stressed. Release of a hot extinguishing agent under high pressure can cause serious injury. 
Wait till the system cools down. 

The BlazeCut fire system is a suppression system only and is not designed or intended to 
extinguish  all  fires.  Where  there  are  high  airflows  and  high  accumulation  of  combustible 
materials,  this  will  dramatically  alter  the  systems  performance.  Always  consider 
supplementary  firefighting  equipment  be  available  in  case  system  does  not  totally 
extinguish a fire. For more information about the use of the system in an area occupied by 
persons, please contact your supplier. 

 

Содержание T Series

Страница 1: ...FULLY This user manual contains important information about the BlazeCut T Series fire suppression system its use operation installation and maintenance If further technical information is required please request a copy of the T Series technical manual from a BlazeCut representative ...

Страница 2: ...tely Following skin contact Flush irrigate the affected area with large amount of water Do not use hot water Remove contaminated clothing affected by extinguishing agent If you experience frostbite seek medical attention Following eye contact Carefully flush irrigate with water for several minutes If possible remove contact lenses if they are inserted Continue flushing Seek medical attention Follo...

Страница 3: ...into one unit The BlazeCut T Series is not compatible with other fire suppression systems do not try to connect the system to any other equipment The system may be installed only by adult persons physically and mentally capable Incorrect interference with the system may cause malfunction of the system and provides threat to safety and health of people The system is under constant pressure any mech...

Страница 4: ...18 ft3 0 11 lb 0 07 oz 11 02 in T050E 0 18 m3 0 14 m3 0 10 kg 2 g 53 cm 6 36 ft3 4 94 ft3 0 22 lb 0 07 oz 20 87 in T100E 0 46 m3 0 35 m3 0 25 kg 5 g 113 cm 16 24 ft3 12 36 ft3 0 55 lb 0 17 oz 44 48 in T200E 0 91 m3 0 69 m3 0 50 kg 5 g 215 cm 32 14 ft3 24 37 ft3 1 10 lb 0 17 oz 84 64 in T300E 1 37 m3 1 04 m3 0 75 kg 10 g 319 cm 48 38 ft3 36 73 ft3 1 65 lb 0 35 oz 125 59 in T400E 1 82 m3 1 39 m3 1 0...

Страница 5: ...oisonous unnecessary excessive exposure of persons to its influence should be avoided Under no circumstances should persons be exposed to the extinguishing agent for more than 5 minutes also in case when the extinguishing concentration does not exceed the LOAEL level contact your local BlazeCut supplier for more information During the system activation the extinguishing agent is discharged from th...

Страница 6: ... with the letter S in model designation have an integrated pressure switch that allows connection of signalling devices or to perform a shutdown operation at agent discharge An IP65 Pressure Switch is factory fitted for outdoor and mobile applications T Series models with the letters S E in model designation have an integrated economy pressure switch that allows connection of signalling devices or...

Страница 7: ...ishing effect of the system may be decreased and part or the entire protected enclosure may be damaged 11 Install the system so that it is not exposed to aggressive chemical substances caustic acids solvents corrosive substances etc and avoid direct influence of weather conditions and direct sunlight 12 When fastening the system make sure not to damage other parts of the vehicle or the enclosure 1...

Страница 8: ...100 min 1 Maximum pressure 60 bar 870 psi Power rating Angular connector All Current Resistive load AC 12 DC12 AC 250 V DC 24 V 4 A Inductive load AC 14 DC14 AC 250 V DC 24 V 2 A IP rating IP65 with cable connector and seal Electrical outlet DIN EN 175301 803 A Operation temperature from 20 C up to 80 C 4 F to 176 F Tested to EN60947 Low voltage switchgear and control gear IEC 68 2 78 Permissible ...

Страница 9: ...er pressure in the tube and vice versa IMPORTANT At very low temperatures the pressure of agent vapours is close to zero Indicator on the pressure gauge can vary from 0 bar 0 psi when temperatures are very low to 17 bar 247 psi when temperatures are very high This is not a sign of defect in the system CASES WHEN THE BLAZECUT SYSTEM MUST BE REPLACED The system is leaking was used or emptied from ot...

Страница 10: ... waste NEED SOMETHING MORE If there is a requirement for electronic monitoring external alarm or other size of system these are available Please contact technical blazecutgroup com GLOBAL HEAD OFFICE BlazeCut Pty Ltd 45 Evans St Balmain NSW 2041 Australia Tel 61 2 8006 1300 MANUFACTURER BlazeCut s r o Priemyselná 2521 90027 Bernolákovo Slovakia www blazecut com technical blazecutgroup com BlazeCut...

Отзывы: