The installation must conform with local codes or, in the absence of local codes, with either
the national Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas
Installation Code or CAN/CGA-B149.2, Propane Installation Code.
1. This gas appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at the test pressures in excess of 1/2
psi (3.5 kPa).
2. This appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the as supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
The Power Burner is
Not
supplied with a Natural Gas Regulator and can be directly connected
to a pre-regulated Gas Line set to 4” WC pressure but must have a shutoff valve available for
quick shut off. We suggest you contact your local fire department / City and building department
and see what rules/regulations they suggest for a safe hook-up and what permits are required.
Always use a professional licensed contractor to make safe connections. Only use a stainless
steel flex gas line to connect the power burner and make sure it is at least ½” as the burner
consumes a lot of gas.
This Power Burner is fuel convertible and comes with a conversion kit to change to the opposite
gas. Please make sure you use a licensed professional to convert and test the power burner.