ALLOWABLE TERMINATION LOCATIONS
Canadian Installations
1
US Installations
2
____________________________________________________________________________________________________
A= Clearance above grade, veranda
*(min. 12”/30 cm)
*(min. 12”/30 cm)
porch, deck or balcony
____________________________________________________________________________________________________
B= Clearance to window or door
*(min. 12”/30 cm)
*(min. 12”/30 cm)
that may be opened
____________________________________________________________________________________________________
C= Clearance to permanently closed
*(min. 12”/30 cm)
*(min. 12”/30 cm)
window
____________________________________________________________________________________________________
D= Vertical clearance to ventilated
*min. 25-1/2” (65 cm)
*min. 25-1/2” (65 cm)
soffit located above the terminal
check with local
check with local
from the centerline of the terminal
code
code
________________________________________________________________________________
E= Clearance to unventilated soffit
*min. 25-1/2” (65 cm)
*min. 25-1/2” (65 cm)
from the centerline of the terminal.
____________________________________________________________________________________________________
F=Clearance to outside corner
*min. 10”/25cm
*min. 10”/25cm
from the centerline of the terminal.
____________________________________________________________________________________________________
G=Clearance to inside corner
*min. 16”/40cm
*min. 16”/40cm
the centerline of the terminal.
____________________________________________________________________________________________________
H= Clearance to each side of centerline
3’ (91cm) within a height 15’ (4.5m)
*
extended above meter/regulator assembly
above the meter/regulator assembly
____________________________________________________________________________________________________
I= Clearance to service regulator vent outlet
3’ (91cm)
*
____________________________________________________________________________________________________
J= Clearance to no mechanical air supply inlet
12” (30cm)
9” (23cm)
to building or the combustion air inlet to any
other appliance
____________________________________________________________________________________________________
K= Clearance to a mechanical air supply inlet
6’ (1.83 m)
3’ (91 cm) above if within 10’ (3 m)
horizontally
____________________________________________________________________________________________________
L= Clearance above paved sidewalk or paved
7’ (2.13 m)†
*
driveway located on public property
____________________________________________________________________________________________________
M = Clearance under veranda, porch, deck or
12” (30 cm)‡
*
balcony
____________________________________________________________________________________________________
1
In accordance with the current CSA B149.1,
Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54,
National Fuel Gas Code
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings
and serves both dwellings.
‡ Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
* For clearances not specified in
ANSI Z223.1/NFPA 54
or
CSA B149.1
, one of the following shall be indicated:
a) A minimum clearance value determined by testing in accordance with section 2.23.7, or ;
b) A reference to the following footnote: “Clearance in accordance with local installation codes and the requirements of the gas
Содержание TORINO
Страница 6: ...The torino Page 6 APPLIANCE DIMENSIONS ...
Страница 24: ...The torino Page 24 WIRING DIAGRAMS INTERMITTENT PILOT VALVE Optional Wall thermostat interrupt green wire ...
Страница 25: ...The torino Page 25 WIRING DIAGRAM 120 V AC ...
Страница 26: ...The torino Page 26 LIGHTING INSTRUCTIONS Intermittent Pilot ...
Страница 27: ...The torino Page 27 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions Fig 3 Receiver body ...
Страница 28: ...The torino Page 28 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Страница 29: ...The torino Page 29 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Страница 30: ...The torino Page 30 HANDHELD THERMOSTAT REMOTE CONTROL operation instructions ...
Страница 37: ...The torino Page 37 FUEL CONVERSION ...
Страница 47: ...The torino Page 47 ...
Страница 48: ...The torino Page 48 NOTES SERVICE HISTORY DATE CORRECTIVE ACTION INCLUDE REPLACEMENT PARTS ...