PRINCESS INSERT
LISTED SOLID FUEL BURNING FIREPLACE INSERT MODEL: PI/1010A Tested to:
Report No. 142-S-05-2
UL 1482 / ULC S628 CERTIFIED IN BOTH UNITED STATES AND CANADA
EPA Cert. No. 586
PREVENT HOUSE FIRES- Install and use only in accordance with Blaze
King’s installation and operation instructions. Install and use in a code
complying fireplace only. Stainless steel flue liner is required in Canada
and recommended in the United States. Contact local building or fire
officials about restrictions and installation inspection in your area.
Minimum Clearances To Combustibles
(Measured from Insert/Stove Sides and Top)
A—Side to Combustible Wall
7 in / 178 mm
B—Top to Bottom of Mantel
22 in / 559 mm
C—Side to Combustible Facing
7 in / 178 mm
FLOOR PROTECTION
A non-combustible floor protection is required for all installations extending 16" (in USA) or
18" (in Canada) in front of the door and extending 8" to either side of the door opening. In
addition to the above requirement that portion of the insert which extends out in front of the
fireplace hearth must have a minimum of 1" vertical distance to any combustible material
Electrical rating: (115 VAC, 60 Hz, 0.58 Amps. Risk of electrical shock. Disconnect power before servicing
unit. Do not route power cord in front of or beneath heater). Do not remove bricks or mortar in masonry
fireplace. Do not use grate or elevate fire. Inspect and clean chimney frequently.
U.S. ENVIRONMENTAL PROTECTION AGENCY-
Certified to comply with July, 1990 particulate emission standards.
*Operate with doors closed. Open door to feed fire ONLY. *Do not obstruct combustion air openings.
*Use only high temperature ceramic glass if replacement is necessary, 5 mm thick.
Warning:
Do not operate with cracked or broken glass. Take care not to strike glass with hard objects and
do not slam door shut. Do not build fire close to the glass door. For use with solid fuel only. Other fuels may
cause a house fire or endanger your safety. DO NOT OVERFIRE! IF HEATER OR CHIMNEY GLOWS YOU ARE
OVERFIRING INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
CAUTION
:
HOT WHILE IN OPERATION. DO NOT TOUCH.
KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT
MAY CAUSE SKIN BURNS. READ THIS LABEL AND INSTRUCTION
MANUAL BEFORE OPERATING HEATER.
S/N -
B
A
C
MANUFACTURED IN:
MANUFACTURE DATE
USA:
Canada:
Blaze King Industries
Valley Comfort Systems
146A Street
1290 Commercial Way
Walla Walla, WA.
Penticton, B.C.
99362
V2A 3H5
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
2003
2004
2005
2006
2007
2008
A
A
B
A = 8" (203 mm) measured from each side
of the fuel loading and ash removal openings
B = 16" (406 mm) in USA
B = 18" (457 mm) in Canada
NON-Combustible
Spark Protection
COMBUSTIBLE
Minimum
1" (25.4mm)
Clearance to
Combustible
#0220