INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for SC25
&
$
%
(
(
)5217'(9$17
)
'
%
6,'(
&27e
0DQWOHVKLHOG
'pIOHFWHXUGH
FKDOHXUSRXU
PDQWHDX
Minimum clearances to combustibles
Measured from fi rebox door fl ange
A
Side of door fl ange to combustible
wall.
13.5"
343 mm
B
Top of door fl ange to bottom of
mantel and combustible facing.
(with mantle shield.)
38" / 966 mm
(24" / 610 mm)
C
Side of door fl ange to side
combustible facing.
10"
254 mm
D
Mantle depth maximum.
(with mantle shield part #2067)
12" / 305 mm
(8" / 204 mm)
E
Minimum hearth side extension *
8"*
F
Mimimum hearth front extension
16" USA
18" CANADA
* Measured from each side of the fuel loading and ash removal
openings / mesuré de chaque coté de l’ouverture de la porte de
chargement et du tiroir de cendre