INSTALLATION INSTRUCTIONS cont.
In mobile home installations, the stove must be securely fastened to the fl oor using the tie-downs provided
in the outside air kit.
Use the leg anchor kit (Z2872) to secure stove to fl oor.
ALSO, a #8 ground wire must be attached to the stove and an appropriate ground.
MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS)
A fan kit is required for these installations (See next page for kit and part numbers). Mobile home installations also requires an outside
air kit (Z1726B). Th
ey are easiest to mount before the stove is installed. See instructions packed with each kit.
UNDER NO CIRCUMSTANCES SHOULD THE FRESH AIR TUBE EVER BE INSTALLED
HIGHER THAN THE BOTTOM OF THE APPLIANCE FIREBOX FLOOR
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed precisely. You must also
purchase (from the same manufacturer) and install the ceiling support package, fi re stops (when needed), insulation shield, roof
fl ashing, chimney cap, etc. Maintain the proper clearance to the structure as recommended by the manufacturer.
Chimney connector must be double wall close clearance type with either ULC629 or ULCS610 designation. Single wall pipe is not
allowed in Mobile Homes or in Alcove Installations. Insulated chimney components must be a listed factory built chimney suitable
for use with solid fuels and conforming to, ULC629 in Canada or UL-103HT in the USA. For Mobile home, the chimney needs to be
removable to allow for transportation of the mobile home.
DO NOT INSTALL IN SLEEPING ROOM. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR,
WALL AND CEILING / ROOF MUST BE MAINTAINED.