AF25
MAINTENANCE
THERMOSTAT
This wood heater thermostat has a manufacturer-set minimum low burn rate that must not be altered. It is
against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent
with operating instructions in this manual. If the thermostat malfunctions contact your dealer for replacement
by a qualified installer.
FAN ASSEMBLY
Routine maintenance of the fan assembly on the side of the stove is not required. However, should it become
necessary to replace an individual fan or rheostat, contact your local dealer.
4. Loosen the four door hinge nuts using
a 7/16” wrench. Slide door hinges in to
tighten door seal and out to loosen door
seal. (
Fig. 15
)
5. Put door back on using nuts and bolts.
6.
Repeat paper test (see “LOADING DOOR
GASKET INSPECTION” on page 35).
Fig. 15