180-AF25 v1.11 per PE32 revs
March 15, 2021
Page 16
AF25
FRONT CAST REMOV
AL
1.
Disconnect the two rheostat wires from the
front cast assembly. Open the loading door.
Remove eight 1/4-20 nuts from top brackets
and side posts with a 7/16” wrench. Remove
two 10-24 nuts from analog cat therm using
a 3/8” wrench. Slide the cast assembly away
from firebox and set aside. Position firebox in
front of fireplace opening (
Fig. 1
). To re-attach
the front cast assembly simply reverse these
steps.
STOVE ASSEMBLY
Flue collar assembly removal
1.
Position stove in front of fireplace opening, and
open loading door.
2.
Remove the two nuts from inside the firebox
that hold flue collar assembly in place, use a
9/16” wrench (
Fig. 2
). Ensure gasket is still
fully intact and adhered to flue collar base. Set
flue collar assembly aside until “
flue collar
preparation
” later in installation.
Thermostat rod installation
3.
Ensure fans have not shifted during transport
and are in correct position.
4.
Slide the thermostat rod in from the left side of
cast, ensure the thermostat is fully open with
the set screw making contact with the stop
(see below), then align machined faces of rods,
secure with the supplied set collar. (
Fig. 3
)
Fig. 1
Fig. 2
Fig. 3