PAGE 26
OM-9603
Date Printed: February 15, 2008
Version: 1.02
-A- BACK LOG:
This larger log should be placed in the back of the stove close to the far back wall. The flat
side of (Log A) should rest flush against the flat part of the back bracket with the rough textured side of the
log pointing towards you. The curved part (of Log A) should be facing upwards.
-B- FRONT LOG:
This smaller log fits in the right and left side brackets closest to you. The flat portion (of Log
B) should be placed flush against the back of the bracket. After setting this log in the brackets, the rough
textured side of the log should be pointing outward, facing you.
-C- LEFT TWIG:
This Y shaped log (C) sits on the left side of the front and back logs (A and B). This log (C)
should be placed on the grooves so that the base of the Y is sitting on the groove in the front log and the
right leg of the Y rests on the peg on the back log.
-D- RIGHT TWIG:
On the right side of Log B. there is a groove. Invert the twig so that the legs are pointing
down. Place the left leg of the twig into the groove of Log B and place top portion of twig onto pin. (Note:
hole should already be present in upper portion of twig)
OAK LOG INSTALLATION
A
B
C
D
EMBER PLACEMENT:
Place embers directly
on the front burner tube, leaving a 1/4” gap between the front log and the embers.
WARNING:
DANGEROUS
OPERATING CONDITIONS MAY
OCCUR IF THESE LOGS ARE
NOT POSITIONED IN THEIR
P R O P E R
L O C A T I O N S .
F O L L O W
T H E S E
L O G
INSTALLATION INSTRUCTIONS
Front of Stove
THE AIR SHUTTER SHOULD BE 1/2 OPENED FOR NATURAL GAS AND FULLY OPENED FOR LIQUID
PROPANE.
THESE SHUTTER SETTINGS ARE APPROXIMATE,
THEREFORE THE UNIT SHOULD BE
ALLOWED TO BURN FOR ABOUT 10 MINUTES TO SEE IF ANY FURTHER ADJUSTMENTS ARE TO BE
MADE.
IF SOOTING APPEARS ON THE LOGS OR GLASS THEN THE AIR SHUTTER NEEDS TO BE
OPENED UNTIL THE SOOTING HAS STOPPED.
AIR SHUTTER ADJUSTMENT
The pilot flame must envelope approximately 1/2 of the Millivolt Generator. It must burn clean. All parts must be
lit. If there are any problems, contact your serviceman. Periodic checking of the flame pattern is necessary.
The flame should look approximately like picture above left . The base of the flame must not rise above the
burner plate.
Thermopile
Pilot
Proper Flame Pattern