39
–
B
LAUPUNKT
R
ECOMMENDED
B
OX
D
ESIGNS
- PC
WG
100, 10” S
UBWOOFER
110
70
90
80
100
db
20
50
100
200
HZ
500
SEALED BOX: 0.5 vs. 1.5 cu.ft.
1.5 cu.ft.
0.5 cu.ft.
110
70
90
80
100
db
20
50
100
200
HZ
500
VENTED BOX: 0.5 vs. 1.5 cu.ft.
1.5 cu.ft.
0.5 cu.ft.
110
70
90
80
100
db
20
50
100
200
HZ
500
SINGLE-VENTED BAND-PASS: 1.0 vs. 2.0 cu.ft.
2.0 cu.ft.
1.0 cu.ft.
SEALED BOX
V
T
f
3
SPL
Total box
volume
Freq.
(cu.ft.)
(Hz)
(dB)
0.50
65
84
0.75
62
90
1.00
60
90
1.25
60
90
1.50
64
90
2.00
66
90
Mid-band
effcy
SINGLE-VENTED BAND-PASS BOX
Total box
volume
Mid-band
effcy
Freq.
Freq.
Port tube
length for
3" I.D. port
Port tune
freq.
Sealed
rear box
volume
Vented
front box
volume
Port tube
length for
4" I.D. port
(cu.ft.)
(Hz)
(Hz)
(Hz)
(cu.ft.)
(cu.ft.)
(in.)
(in.)
(dB)
0.75
52
140
85
0.4
0.35
4.4
8.8
90
1.00
45
130
75
0.5
0.5
4.6
9.1
90
1.25
45
110
70
0.6
0.65
4.3
8.6
90
1.50
43
95
65
0.7
0.8
4.2
8.5
89
1.75
38
92
60
0.7
1.05
5.3
10.4
88
2.00
32
95
55
0.7
1.3
6.7
13.0
87
VENTED BOX
V
T
f
3
f
B
P
L
P
L
SPL
Total box
volume
Freq.
Port tune
freq.
(cu.ft.)
(Hz)
(Hz)
(in.)
(in.)
(dB)
0.50
60
40
9.0
<NR>
91
0.75
50
40
5.6
<NR>
90
1.00
42
40
3.8
9.7
90
1.25
38
40
2.8
7.3
90
1.50
35
35
3.1
8.1
90
2.00
32
35
2.0
5.5
90
Mid-band
effcy
Port tube
length for
3" I.D. port
Port tube
length for
4" I.D. port
V
T
f
3L
f
3H
f
B
V
F
V
R
P
L
P
L
SPL
<NR> is
NOT