15
Connecting the hob
Setting up the configurations:
For the different connection types, use the brass bridges in the box next to the terminal.
Single-phase 230V~1P+N:
Place a bridge between terminals 1 and 2.
Connect the earth to the earth connection, the neutral conductor N to terminal 4 and phase L to
one of the terminals 1 or 2.
Two-phase 400V~2P+N:
Connect the earth to the earth connection, the neutral conductor N to terminal 4, phase L1 to
terminal 1 and phase L2 to terminal 2.
Caution!
Frequent loosening and tightening the screws on the connection box may affect their
tightness. Therefore, it is advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed.
We cannot be held responsible for accidents caused by incorrect connection or which may
result from the use of an appliance which is not earthed or which is equipped with an
incorrect earth connection.
Содержание 5RE64361
Страница 47: ......