VENTO SOLAR V60 PRO / VENTO SOLAR V60 S PRO operation modes:
•
In the day time the unit is powered by the solar panel.
~230 V
SEV-T12
Solar panel
Switching module
Control signal
Power supply to
the ventilation
unit (12 V)
•
In the night time or in low light conditions the unit is powered by power mains.
~230 V
SEV-T
Solar panel
Switching unit
Control signal
Power supply to
the ventilation
unit (12 V)
VENTO SOLAR V60 PRO2 / VENTO SOLAR V60 S PRO2 operation modes:
•
In the day time or when the storage battery is charged the unit is powered by the accumulated in the storage battery solar energy.
~230 V
SEV-T12
Solar panel
Switching unit
Control signal
Power supply to
the ventilation
unit (12 V)
•
In the night time, in low light conditions or when the storage battery is discharged the unit is powered by power mains.
~230 V
SEV-T12
Solar panel
Switching unit
Control signal
Power supply to
the ventilation
unit (12 V)