www.blaubergventilatoren.de

3

FRESHBOX E120

BLAUBERG Ventilatoren GmbH

 Company is happy to off er your attention  

single-room heat recovery air handling unit 

FRESHBOX E120

.

INTRODUCTION

The present operation manual contains a technical description, technical 

data sheets, operation and mounting guidelines, safety precautions and 
warnings for safe and correct operation of the unit. Read carefully and 
understand the operation manual, especially the safety requirements, before 
the unit mounting and start up. Keep the operation manual available as long 
as you use the unit.

GENERAL

The heat recovery air handling unit is designed for effi

  cient and energy 

saving ventilation of fl ats, houses, cottages and other small premises. 

The unit is designed for wall mounting. The unit is available for round Ø125 

mm air ducts. The unit is rated for non-stop operation.

The unit is rated for indoor application at ambient temperature from +1 °C 

up to +60 °C and relative humidity not exceeding 80%. The transported air 
temperature must be within -25 °C  up to +50 °C.

Hazardous parts access and water ingress protection rating:

…

 

Unit motors - IP 44;

…

 

Assembled unit connected to air ducts - IP 22.

The unit design is regularly improved, so some models can slightly diff er 

from those ones described in this service instruction. 

SAFETY RULES

All operations related to the unit electrical connections, servicing and 

repair works are allowed only after the unit disconnection from power mains.  

The unit is rated as a Class I electrical appliance. All mounting and servicing 

operations are allowed by duly qualifi ed personnel. Please follow the safety 
regulations and working instructions (DIN EN 50 110, IEC 364).

Make sure the impeller and the casing are not damaged before connecting 

the unit to power mains. The casing internals must be free of any foreign 
objects which can damage the impeller blades. The unit maintenance and 
repair is allowed only after power cut-off  and full stop of the rotating parts.

Misuse of the unit or any unauthorized modifi cation are not allowed. 
The unit is designed for connection to ac single-phase power mains, see 

«Technical Data». 

The unit is rated for permanent operation. Take steps to prevent ingress 

of smoke, carbon monoxide and other combustion products into the room 
through open chimney fl ues or other fi re-protection devices. Suffi

  cient 

air supply must be provided for proper combustion and exhaust of gases 
through the chimney of fuel burning equipment to prevent back drafting.  
The maximum permitted pressure diff erence per living units is 4 Pa.

The transported air must not contain any dust or other solid impurities, 

sticky substances or fi brous materials.

The unit is not rated for operation in a fl ammable or explosive medium. 
Fulfi l the operation manual requirements to ensure a trouble-free and long 

service life of the unit.

TRANSPORTATION AND STORAGE RULES

Transportation of the unit is allowed by any vehicle provided the unit is 

transported in the original package and is protected against weather and 
mechanical damages. 

Use hoist machinery for handling and transportation to prevent possible 

mechanical damages of the unit. Fulfi l the requirements for transportation of 
the specifi ed cargo type during cargo-handling operations. 

Store the unit in a dry and cool place in the original packing. The storage 

environment must not be subjected to any aggressive and/or chemical 
evaporations, admixtures, foreign objects that may provoke corrosion and 
damage connection tightness. 

Store the unit in an environment with minimized risk of mechanical 

damages, temperature and humidity fl uctuations. Do not expose the unit to 
the temperatures below  +10 °C and above  +40 °C .

Connection of the unit to power mains is allowed after the unit  has been 

kept indoor for minimum two hours.

MANUFACTURER’S WARRANTY 

The unit complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-
Directives on Electromagnetic Compatibility. 

We hereby declare that the unit complies with the essential protection 

requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC 
and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 
93/68/EEC on the approximation of the laws of the Member States relating to 
electromagnetic compatibility. This certifi cate is issued following test carried 
out on samples of the product referred to above. Assessment of compliance of 
the product with the requirements relating to electromagnetic compatibility 
was based on the following standards.

The manufacturer hereby warrants normal operation of the unit over the 

period of two years from the retail sale date provided observance of the 
installation and operation regulations. In case of failure due to manufacturing 
fault during the warranty period the consumer has the right to exchange it.

The replacement is off ered by the Seller. 
If case of no confi rmation of the sale date, the warranty period shall be 

calculated from the manufacturing date.

The manufacturer shall not be liable for any damage resulting from any 

misuse of or gross mechanical interference with the unit.

The manufacturer is not responsible for the damages resulted due to the 

use of  third party equipment or to third party equipment.

                   

WARNING

Do not dispose in domestic waste. 

The unit contains in part material that 

can be recycled and in part substances that should 
not end up as domestic waste. Dispose of the unit 
once it has reached the end of its working life ac-
cording to the regulations valid in your country.

 

                  

WARNING

The unit is not allowed for use by chil-

dren and persons with reduced physi-

cal, mental or sensory capacities, without proper 
practical experience or expertise, unless they are 
controlled or instructed on the product operation 
by the person(s) responsible for their safety. Super-
vise the children and do not let them play with the 
product. 

!

Содержание FRESHBOX E120

Страница 1: ...OPERATION MANUAL FRESHBOX E120 SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT EN ...

Страница 2: ...rtation and storage rules 3 Manufacturer s warranty 4 Design 4 Operating logic 5 Delivery set 5 Technical data 6 Mounting 8 Connection to power mains 9 Unit control 14 Maintenance 16 Troubleshooting and fault handling 17 Acceptance certificate 17 Connection certificate 17 Warranty card CONTENTS ...

Страница 3: ...TATION AND STORAGE RULES Transportation of the unit is allowed by any vehicle provided the unit is transported in the original package and is protected against weather and mechanical damages Use hoist machinery for handling and transportation to prevent possible mechanical damages of the unit Fulfil the requirements for transportation of the specified cargo type during cargo handling operations St...

Страница 4: ... drain pan under the heat exchanger unit is designed for condensate collection As the drain pan is filled with condensate the unit is turned off and the status is displayed by the indicator on the control panel Empty the condensate from the drain pan and restart the unit The unit is equipped with a 350 electric posistor heater used for operation of the unit at low outside air temperatures The elec...

Страница 5: ... panel G2 Supply filter panel G4 Replaceable filter kit FP FRESHBOX E120 Connected air ducts diameter mm 125 Weight kg 20 Heat recovery efficiency 82 up to 92 Heat exchanger type counter flow type Heat exchanger material polystyrene replaceable filter kits and summer blocks are specially ordered accessories and are available on a sepa rate order Fig 2 Overall dimensions DELIVERY SET 9 Air handling...

Страница 6: ...ir ducts Ø 125 mm of required length must be provided MOUNTING Safety precautions The unit must be mounted to a rigid and stable structure The unit mounting is performed by means of anchor bolts Before starting mounting check that the mounting structure has sufficient loading capacity for the unit weight The unit mounting is allowed only after power cut off and full stop of the rotating parts Warn...

Страница 7: ... outer side Insert the air ducts into the mating master plate holes and connect those to the outer hood connection piece Fix the gaps between the air ducts and the wall with a mounting foam through openings in the master plate After the mounting foam hardening remove the master plate the foam excess and cut the protruding parts of the air ducts to be flush with the wall Open the unit panel and rem...

Страница 8: ...OFF position prior to any operations Take steps to prevent activation of the automatic switch QF CONNECTION TO POWER MAINS WARNING Read the operation manual prior to any electric installations Connection of the unit to power mains is allowed by a qualified electrician only The rated electrical parameter are stated on the rating plate No modifications of internal connections are allowed and will re...

Страница 9: ... Control panel display in OFF mode Fig 9 Control panel display in ON mode Unit ON OFF Operation control buttons see details below Fan speed control buttons Remote control Remote Controller Unit ON OFF Fan speed UP Heater ON Heater OFF Fan speed DOWN Low speed ON High speed ON Medium speed ON Scheduled operation ON Timer ON OFF Control panel Countdown indication of the time required for heat remova...

Страница 10: ...old seasons Heater activation deactivation via the control panel press and hold press Heater activation via the remote control Heater deactivation via the remote control WARNING The unit continues operating within 30 seconds after turning off to ensure heat removal from the heating elements 4 Timer The timer ensures automatic changeover from a current operation mode into high speed mode and revert...

Страница 11: ...selection or Supply fan power step up and step down Each pressing increases decreases the fan power by 1 press and hold press stepping up stepping down Current supply fan power indicator during set up Current supply fan power indicator Supply fan adjustment indicator when pressed Extract fan power step up down Each pressing increases decreases the fan power by 1 press and hold press stepping up st...

Страница 12: ...e filters as stated in the Maintenance section After the filter replacement connect the unit to power supply and press a respective button on the control panel or on the remote control to activate the unit or Resetting motor hours press synchronously and 7 Date and time setting Press a respective button on the control panel to deactivate the unit Changeover to the date and time setup mode press an...

Страница 13: ...ter off Heater on press and hold press Selection of the scheduled operation mode parameters The set point blinks during setup press and hold press or Setting the required set point Parameters for scheduled operation setup Entry number each week day has four entries Week day setting week day Heater operation status setting the heater operating status for a current entry Fan speed setting the fan sp...

Страница 14: ...flush it with water After two consecutive cleanings the filter must be replaced Install dry filters only Contact a local distributor for the filters stated above in the section Technical data Dirty filters are not considered as a warranty case Replace immediately humid and mouldy filters Filter removing as follows Make sure the unit is disconnected from power mains QF Open the unit panel Remove th...

Страница 15: ... full drain pan status and the need to remove condensate Condensate removal Make sure the unit is disconnected from power mains QF Open the unit panel Lift up the condensate level switch Hold the condensate level switch and pull carefully the condensate drain pan Empty the drain pan and re install it back Lift up the condensate level switch prior to its installation 5 Outer ventilation hood supply...

Страница 16: ...rt when the unit is on No power supply or wrong connection to power mains Connect the unit to power mains Troubleshoot the connection error Jammed motor soiled impeller blades Remove the motor jam clean the impeller blades Automatic switch tripping Short circuit in power grid Turn the unit off and contact the seller for troubleshooting Low air flow Too low set speed Set higher speed The filters an...

Страница 17: ...ge Directive 2006 95 EC 73 23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date ____________________ Company Name Date Signature Single room heat recovery air handling unit FRESHBOX E1...

Страница 18: ...________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________...

Страница 19: ...www blaubergventilatoren de FRESHBOX E120 v 1 5 10 2014 EN ...

Отзывы: