www.blaubergventilatoren.de
S25
9
Main page
Buttons:
— unit ON/OFF (Standby mode activation).
2
— press the arrows as many times as necessary to select the desired pre-set speed.
%
50
— manual speed selection mode (from the minimum permissible pre-set value to 100 %).
%
— displayed upon pressing
, adjust the speed (up/down) by pressing the arrows as many times as necessary. To revert to the pre-
set speeds, press the percentage icon
%
.
ON
/
OFF
— timer activation/de-activation, to adjust the timer settings go to the Timer window.
ON
/
OFF
— weekly schedule activation/de-activation, to adjust the settings to the Schedule window.
Indicators:
— Warning. The current warnings are shown in the Alarms window (
Main page
Menu
Alarms
Current alarms
).
— Filter replacement alert (
Main page
Menu
Basic settings
Filter
).
—
Fireplace
mode (
Main page
Menu
Engineering menu
Temperature
).
Boost
—
Boost
mode (
Main page
Menu
Engineering menu
Temperature
).
— Electric preheater or reheater blowing prior to air handling unit shutdown.
— Return water heater prior to AHU activation in winter.
Sensors:
— current temperature readings from the selected sensor in the supply air duct, extract air duct or in the room.
%
,
CO2
,
PM2.5
,
VOC
— current readings from the humidity, CO2, PM2.5, or VOC sensor respectively.
If the AHU is configured with both the main and external sensors, the control panel shows the readings from the main sensor only.
Sensor set-up:
Main page
Menu
Basic settings
Air quality
Sensor activation/de-activation:
Main page
Menu
Engineering menu
Sensors
Sensor indicator colour:
• Grey — no sensor detected.
• Blue — sensor readings below the pre-set value.
• Red — sensor readings exceed the pre-set value.
MAIN MENU
— screen lock button.
CONTROL
Содержание S25
Страница 1: ...Sensor control panel EN S25 USER S MANUAL ...
Страница 20: ...www blaubergventilatoren de B206EN 01 ...