5.1 Preparations for Starting
Regular inspections are important to prevent unscheduled downtime
of the scarifier. Before starting carry out the following tests.
ASSURE THE MACHINE IS IN “MAINTENANCE MODE” WHEN
DOING THESE CHECKS. See Section 1.7 for “Maintenance Mode”
details.
a)
Verify that all machine components have been correctly assembled.
b)
Verify that all screws and other fasteners are tight.
c)
Check the scarifier drum for foreign material and remove.
d)
Check the scarifier drum, housing and fastening screws for damage
and wear.
e)
Check the flexible dust collector tubing and connections for leaks and
repair or replace when necessary.
f)
Verify that the dust container of the dust collector is empty
g)
Check the electrical connections for dirt and deposits of foreign
material.
h)
Check the electric motor for dirt and other contaminants.
i)
Bring the scarifier and the dust collector to the surface to be scarified.
To move the machine by hand, tip the machine back slightly. See
Section 3.3 “Mechanical Operating Elements”.
j)
Check the main electrical cable for damage. Replace and repair all
damaged parts before starting the machine.
k)
Connect the dust hose to the scarifier and the dust collector. Use hose
clamps at the connections.
l)
Connect the electrical cable for the dust collector to site power
connection.
Before starting make sure that all safety guards and housings are in
place and that the dust collector has been correctly connected
Handle all plugs, cable and operating elements with care. Avoid
contact with live conductors.
If problems occur with the power supply during assembly and/or
starting, contact a qualified electrician. Any work performed on
electrical parts may only be carried out by qualified personnel.